LPCB(EN54-2/4) CE approval addressable fire alarm control panel new technology with Black box function etc. Color menu display Intelligent bus control mode; max 255 addressable points per loop, max 4 loops, max 48 zones Loop card type design:1-4 loop card can be selected Glass fuse per loop Black box function Independent controlling password for the specially needed gas recharging units Self-design loop protocol Wall-mounted structure, compact and exquisite Language: simplified Chinese and English Approvals:LPCB(EN54-2/4) CE Technical Specifications Mains supply AC 230V (50HZ),Voltage range: +10%~-15% Standby battery 12V/12AH sealed lead acid battery *2 LCD screen size 7-inch color LCD screen Operating Environment Temperature: -5°C~+50°C;Relative Humidity: ≤95%, non-condensing Capacity 1020 addressable points Communication Interface RS232、RS485、C A N、U S B Dimension (L×W×H) 420mm×140mm×560mm Output Five output. Fault output. 24V power output. Loop output
$990.00 $810.00Works with TC series addressable fire alarm system Intelligent heat detector Advanced single-chip microcomputer technology Non-polarized two-wire Indoor garage, kitchen, boiler room, generator room, drying room and other places Approval: LPCB(EN54-5) CE Technical Specifications Operating voltage Loop 24V(18.5V~26V) Operating current Standby current: ≤0.3mA; Alarm current: ≤0.8mA Operating Environment Temperature: -10°C~+50°C; Relative Humidity: ≤95%, non-condensing Indicator Red,Flashes when polling,Illuminates in alarm Ingress protection rating IP33 Material and color of enclosure ABS; Milky white Coding method Electronically coding Code range 1~255 Weight About 110g Mounting hole distance 60mm Dimension 100mm×50mm (with base)
$14.90works with TC series addressable fire alarm system Hotel, restaurant, warehouse, library, office building, teaching building fire security equipment smoke sensor fire detection system. Infrared scattering principle Non-polarized two-wire Drift compensation and fault detecting function Reporting dirt fault Hotel, restaurant, warehouse, library, office building, teaching building, power plant and other places Approvals:LPCB(EN54-7) CE Technical Specifications Operating voltage Loop 24V(18.5V~26V) Operating current Standby current: ≤0.3mA;Alarm current: ≤0.8mA Operating Environment Temperature: -10°C~+55°C,Relative Humidity: ≤95%, non-condensing Indicator Red,Flashes when polling,Illuminates in alarm Ingress protection rating IP23 Material and color of enclosure ABS; Milky white Coding method Electronically coding Code range 1~255 Weight About 110g Mounting hole distance 60mm Dimension 100mm×51mm (with base)
$14.90DC24V LPCB Approved resetable manual fire alarm call point Addressable fire alarm button works with TC series addressable fire alarm system. Installed in public places; when there is a fire, pressing the frangible element on this MCP can send fire signal to fire alarm control panel Alarm by pressing, reset by a special key Non-polarized two-wire to the control panel Reusable Approvals:LPCB(EN54-7) CE Technical Specifications Operating voltage Loop 24V(18.5V~26V) Operating current Standby current: ≤0.2mA;Alarm current: ≤0.8mA Operating Environment Indoor Temperature: -10°C~+55°C;Relative Humidity: ≤95%, non-condensing Indicator Red. Flashes about every 3s when polling;Illuminates after in alarm Coding method Electronically coding Code range 1~255 Material and color of enclosure ABS; Red Weight About 120g (with base) Mounting hole distance 60mm Dimension (L×W×H) 95mm×44mm×95mm (with base)
$14.90Audio and visual alarm device used to warn people in field It works with TC series addressable fire alarm system. It has LPCB approval Installed in public places A kind of audio and visual alarm device used to warn people in field when fire occurs Four wires:non-polarized signal two-wire, and non-polarized DC24V power two-wire Built-in microprocessor Self-diagnostic function Electronically coding Approvals: LPCB(EN54-3) CE Technical Specifications Operating voltage Loop: 24V (16V~28V);Power: DC24V (DC19V~DC28V) Standby current Loop: ≤0.2mA;Power: ≤0.5mA Active current Loop: ≤1.5mA;Power: ≤50mA Operating Environment Indoor (Non-residential);Temperature: -10°C~+50°C; Relative Humidity: ≤95%(40±2°C) Sound level 80dB~115dB (A weighted) Pitch shift periodic 3.5S~4.5S Basic flashing frequency 1Hz~2Hz Weight 200g Dimension (L×W×H) 115mm×55.3mm×140mm
$16.80TCSB5214H TC fire alarm system series LPCB approval addressable 2-wire bus type Voltage: Loop DC24V(16V-28V) Digital Manual Call Point (With Jack) (MCP) is installed in public places. The MCP contains a phone jack. And when there is a fire, pressing the frangible element on this MCP can send fire signal to Fire Alarm control panel. After receiving the signal, the control panel will show address information of the MCP and generate alarm sound. Insert the Fire Telephone handle into the phone jack, and then communicate the fire telephone panel. Features 1.Plug-in structure. Simple and convenient installation. Alarm by pressing, reset by a special key. 2.Pressing the frangible element and it can provide independent output contact through the MCP. And it can directly control other peripheral devices. 3.Microprocessor processes signal and digital signal communicates the Fire Alarm Control Panel. Stable and reliable work, good ability to inhibit electromagnetic interference. 4.Electronically addressed. The address can be modified in field. Easy and reliable for commissioning. Technical Specifications 1.Operating voltage Signal bus voltage: loop 24V 2.Operating current Standby current: ≤ 0.2mA Alarm current: ≤ 0.8mA 3.Type of initiating part: Reusable 4.0Initiating mode: Pressing the frangible element manually 5.Resuming mode: Manually resumed by a special key 6.Indicator Running/fire LED: Red. Flashes every 3s when polling. Illuminates after alarming. Fire telephone: Red. Flashes every 5s. 7.Programming mode Electronically addressed (address range: one address within 1~255). 8.Wiring Non-polarized signal two-wire 9.Operating environment Class: indoor Temperature: -10°C~+55°C Relative Humidity: ≤95%, non-condensing 10.Dimension Diameter: 90mm×90mm×42 mm (with base) 11.Material and color of enclosure: ABS; red 12.Weight: about 120g(with base) 13.Mounting hole distance: 60mm 14.Standard: GB 19880-2005 Call Point with Jack
$15.90Addressable Single I/O Module LPCB intelligent Module Designed to connect with linkage devices of fire alarm control panel, such as exhaust valve, air valve, fire damper etc., and can receive feedback signal from device Non-polarized two-wire Active and passive output The input terminal can be in field set to normally open detecting wire or self-feedback mode, which can be connected with passive contact Approvals: LPCB(EN54-18) CE Technical Specifications Operating voltage Loop:24V (18.5V~26V);Power: DC24V (DC19V~DC28V) Standby current Loop: ≤0.2mA;Power: ≤2mA Starting current Loop: ≤2mA;Power: ≤22mA Operating Environment Temperature: -10°C~+55°C;Relative Humidity: ≤95%, non-condensing Output capacity Passive:Capacity: DC30V/3A;Contact resistance in normal condition: 100kΩ;Closed when activated;Suitable for DC or AC12V~48V;Active output: DC24V/1.5A Indicator Red,Input indicator,Flashes when polling,Illuminates in action,Output indicator,Illuminates in action Coding method Electronically coding Code range 1~255 Material and color of enclosure ABS; Porcelain white Weight About 147g (with base) Mounting hole distance 60mm Dimension (L×W×H) 86mm×38mm×86mm (with base)
$16.00NAJ2214 Addressable Fire Extension Telephone handle works with TCSB5214H or same brand telephone jack It is a bus communication device special for fire protection system. The extension can transmit and receive signals with a Fire Telephone control panel. It is suitable for hotels, restaurants, office buildings, teach buildings, banks, warehouses, libraries, computer rooms and switching rooms. In traditional fire management, some information is managed in the form of paper files. Not only is the data record not comprehensive enough, but also it is difficult to consult and manage because data management is not applied. Tiancheng home safety all-wireless products are combined with the cloud platform, which can fully record and manage all the operation traces of equipment implementation. When the equipment fails, the system will automatically report it to the management party and the maintenance party, and the follow-up inspection and maintenance work will also be recorded in the whole process, so as to change the fire control work mode and further improve the fire control work management efficiency. Frequency Range: 300-3400Hz Operating Current: < 22mA Operating Environment: Temperature: - 10°C~+55°C; Relative Humidity: <95% Function: Matched with NAJ2213&NAJ2215 Dimension: 204 mmx 50mmX 38mm Mounting Hole Distance: 100mm Approval: CCCF
$13.50Stay Updated with Offers & New Arrivals
Send message to us with your email address. One click from the bottom right of the home page and send us your message.
TCZS5273 Detector remote indicator light...
TCMK5265 Addressable I/O Module non-pol...
© Copyright 2018~2025 by vedard.com