Residual Current Transformer TC-DH01B-J325 Through-line aperture: 325 × 60mm main circuit rated operating current: less than 1000A Dimensions: 445mm × 220mm × 60mm Connected to the monitoring device JB-DH-TC5600 with a non-polar two buses, while achieving communication and power supply functions The address code is electronically encoded and can be written in advance by the electronic encoder. The engineering debugging is simple and reliable The microprocessor monitors the operation and transmits the status of the module to the monitoring device in both normal and alarm modes Wire system: non-polar connection to the signal bus of the monitoring device Residual current detector Specification: 1. Operating Voltage: Pulse voltage of circuit loop: Loop 24V Available range: 16V~30V 2. Operating current: Standby current≤0.4mA Alarming current≤0.7mA 3. Rated alarming current: 200mA~1000mA, step-size 1mA 4. Encoding mode: electrical addressable mode. It takes one site on the loop. And an addressable code could be any in the range of 1~255. 5. Cabling: connecting with the monitoring devices through signal nonpolar two-line loop. 6. Aperture of wires: 325mm×60mm 7. Rated operating current of main loop: less than 1000A. 8. Rated frequency of wires: 50Hz/60Hz 9. Ambient environment: Temperature: -10℃~+55℃ Relative humidity≤95%, non-condensing 10. Dimension: 445mm×220mm×60mm 11. Enclosure material: ABS plastic 12. Ingress Protection Rating: IP30 13. Weight: about 8kg
$120.00Intelligent Fire Alarm control panel LPCB fire controller 1 Loop 255points (it is also available for 2/3/4 loops). Color menu display Intelligent bus control mode; max 255 addressable points per loop, max 4 loops, max 48 zones Loop card type design:1-4 loop card can be seledted Glass fuse per loop Black box function Independent controlling password for the specially needed gas recharging units Self-design loop protocol Wall-mounted structure, compact and exquisite Language:English Approvals:LPCB(EN54-2/4) CE Product installation manual and at alarm system
$800.00Back lit LED displaying all the information Display Capacity: Max 1024 pieces of scrolling information Simultaneous audible and visible alarming signals with the control panel MUTE, UP, DOWN and BROWSE operational keys are available
TX7201 Addressable Zone Monitor unit is an addressable interface module, which will integrate conventional detectors or conventional manual call points to addressable system. When any of the connected devices alarms are active, the unit can send the alarm message to fire alarm controller, which generates alarm signal and displays its address. The unit can match with the conventional optical smoke detector, conventional rate of rise and fixed temperature detector and conventional manual call point etc. It has the function of checking short or open circuit of the output connection, by the End of Line Resistor (EOLR). The fault massage includes open circuit, short circuit or any removal of the detectors.
Residual Current Electrical Fire Monitoring Detector TC-DH01B-J225 Through-line aperture: 225 × 56mm main circuit rated operating current: less than 630A Dimensions: 296mm × 166mm × 45mm Standard: GB14287.2-2014 "Electric Fire Monitoring Systems - Part 2: Residual Current Electric Fire Detectors” The Detector builds up an electrical fire monitoring system with our productions of JB-DH-TC5600 Electrical Fire Monitoring Equipment, TC-DH12A Combined Electrical Fire Monitoring Detector and TC-DH230 Combined Electrical Fire Monitoring Detector. The Detector can realize the function of leakage test, temperature test and output controlling by connecting with JB-DH-TC5600 Electrical Fire Monitoring Equipment through two-line loops. It can also connect with many other kinds of residual current transformers to realize stable and reliable operating. Electrical fire monitoring system can effectively prevent electrical fires and reduce losses. Technical Specifications: 1. Operating Voltage: Pulse voltage of circuit loop: Loop 24V Available range: 16V~30V 2. Operating current: Standby current≤0.4mA Alarming current≤0.7mA 3. Rated alarming current: 200mA~1000mA, step-size 1mA 4. Encoding mode: electrical addressable mode. It takes one site on the loop. And an addressable code could be any in the range of 1~255. 5. Cabling: connecting with the monitoring devices through signal nonpolar two-line loop. 6. Aperture of wires: 225mm×56mm 7. Rated operating current of main loop: less than 630A. 8. Rated frequency of wires: 50Hz/60Hz 9. Ambient environment: Temperature: -10℃~+55℃ Relative humidity≤95%, non-condensing 10. Dimension: 296mm×166mm×45mm 11. Enclosure material: ABS plastic 12. Ingress Protection Rating: IP30 13. Weight: about 3kg
$60.00▪ The non-polar two buses are connected to the monitoring device to realize the communication and power supply functions at the same time. ▪ The address code is electronical, which can be written in advance by the electronic encoder. The engineering debugging is simple and reliable, which can also be set directly on the machine ▪ The microprocessor monitors the operation and transmits the status of the module to the monitoring device in both normal and alarm modes. ▪ Wire system: Non-polar connection to the signal bus of the monitoring device ▪ Line rated frequency: 50Hz/60Hz ▪ Dimensions: 92mm × 59mm × 110mm How to use the combined electric fire monitor detector? Each combined electric fire monitor detector is installed in one power distribution box. It has 8 channels and can accept input of residual current detection or high temperature detection signal. The residual current detectos' outlet loops and temperatures detectors' outlet loops will be funneled into the combined electric fire monitor detector. Then it connects to addressable electric fire monitor panel TC-5600. From the TC-5600, you can set the residual current alarm value. What can the combined electric fire detector do? How to wire and encode it?
$45.00TX7130 Conventional Reflective Beam Detector has built in Laser beam pointing and Digital guide display for real user friendly alignment method. The Laser beam pointing accurately point the exact location where to mount mirror and with additional digital guide display allows to monitor and guide on the actual light intensity between the mirror and detector which cannot be seen by our naked eye making it more easy and convenient in alignment commissioning. The TX7130 has four adjustable operational ranges of between 8 to 20, 20 to 40, 40 to 70 and 70 to 100 meters beside with three adjustable sensitivity setting ranges from 2.6dB, 3.8dB and 5.8dB to meet the specific environmental requirement. The TX7130 works on the principle of reflective infrared beam obscuration. Used in conjunction with a reflector, it will notify the fire alarm panel when the infrared beam is obscured by smoke. The TX7130 is ideal for use high ceiling and wide areas such as warehouses, large storages, shopping malls, leisure centers, exhibition halls, hotel lobbies, printing houses, garment factories, museums and prisons, as well as places where slight smoke particles or corrosive gas exist.
The detector can work independently or connect with JB-DH-TC5600 electrical fire monitoring equipment through two bus circuits, and realize the functions of leakage detection, temperature detection and output control. It works stably and reliably, and is connected with a variety of residual current transformers according to the magnitude of the over-line current. How to install electric fire monitoring system? Features 1.The Detector and the Electrical Fire Monitoring Equipment use non-polarized two-line system to connect. With mature technology, it is reliable in communication and convenient in cabling. 2. The Detector uses a high-performance CPU, intelligent algorithm and watchdog technology, highly efficient and reliable. 3. The Detector has a built-in passive output control which can connect with one or two loops to alarm leakage. 4. The Detector has the function of self-test which can test the screen and squealers working normally or not. 5. The Detector can set the residual current from 200mA to 1000mA of residual current transformers, which is high- precision detecting and widely used. It can be programmed with address and convenient for commission and maintenance. 6. The alarming temperature can be set from 45℃ to 140℃, high-precision detecting and widely used. It is convenient for commission and maintenance by the setup of addressable code and temperature. 7. The Detector has a good-looking appearance with intuitive showing of LCD information, simple operation and powerful functions, scalability and easy to installation. Technical Specification 1. Operating voltage: AC 220V 2. Operating current: ≤10mA 3. Alarming current: ≤25mA 4. Rated alarming current: 200mA~1000mA, step 1mA 5. Rated alarming temperature: 45℃-140℃, step 1℃ 6. Loop interface: Loop 24V, non-polarized 7. Capability of output terminal: 1A/AC125V,3A/DC24V 8. Response time: ≤10s 9. Rated frequency through the line: 50Hz/60Hz 10. The parameters of residual current transformer can be seen in chapter 5.3 11. Operating environment: Temperature: -10℃~+50℃ Relative Humidity: ≤95%, no condensation Altitude: <5000m 12. IP Grade: IP30 13. Weight: about 420g 14. Standard: GB 14287.2-2014“Electrical fire control system - Part 2: residual current electric fire detectors” GB 14287.3-2014“Electrical fire monitoring systems -Part 3: The temperature electric fire detectors” 4. Structure and Working Principle: 1. Refers to Fig.1 for the appearance of detector 2. Working principle The Detector receives the information from the sensor. When the information sent by the sensor reaches the setup value of threshold, the detector will send audible and visual alarm, and the screen will display the current alarm at the same time. If the Detector has been connect with the loop, the detector can upload alarm, faults and some other information to the electrical fire monitoring equipment and execute the order of the equipment.
$160.00Bus communication 1 loop or 2 loops electric fire monitor controller. This monitoring panel should work with DH12A, DH01B and DH230 electrical fire detectors to form an electrical fire monitoring system. Each detector has its own independent coded address and alarm information is reported to the control panel. At the same time, each channel of the bus device is disconnected or short-circuited, and the communication fault of the device is reported to the host JB-DH-TC5600 Electrical Fire Monitoring Equipment. Video guidance to set up the electric fire monitor system Features and specifications: Large screen LCD screen, various alarms, faults, status and other information are displayed. Residual current detector, temperature sensor alarm value has wide range adjustable, wide adaptability The detector is electronically coded by easy and convenient installation The function of interconnecting with our fire alarm system Maximum 2 loops with 255 electrical fire detectors per loop bus The casing meets the requirements of IP30 strictly, and all gaps and vents are no more than 2.5mm Controller dimensions (L × W × H): 360mm × 130mm × 480mm Working environment: -10°C~50°C, humidity<=95% Power: 50Hz, AC220V+10%-15% backup battery: 24V/3.3AH Weight: 8kg Executive standard: GB4717-2005
$310.00Fire alarm relay output Fault relay output IR2 EXdIICT6 Product function and composition A705/IR2 can be applied to the need to monitor the implementation of the fire place, quickly found that the fire may cause the burning flame, issued in a timely manner Fire alarm. A705/IR2 is converted to electrical signal by two infrared pyroelectric sensors which work in different bands. Signal input industrial computing chip for comparison, operation and processing, with the detecter&anysafe II Ir dedicated intelligent control software, you can Send out a fire alarm in time. A705/IR2 uses the aluminum die-casting flameproof shell, has good protective properties and explosion-proof, corrosion resistance, aging resistance, can work for a long time In the indoor, outdoor and all kinds of special industrial places. Sensor sharp probe AE-S708/4 and AE-S708/5 infrared pyroelectric sensor Optical window :white gems (Al2O3) housing L material: aluminum alloy L molding process: Die Casting L coating process: surface electrostatic powder coating, internal metal passivation treatment. The weight is less than 1kg Explosion proof and protection l anti explosion: EXd II CT6 L protection: IP66 Working parameters Project specifications or status Minimum standard of power supply 18VDC (can be customized 12VDC) 30VDC 24VDC The current monitoring status of less than 15mA, the alarm state is less than or equal to 35mA Pre heating time 60s Fire alarm when the monitored area is found in the fire, the detector into the fire state; Fire alarm output relay action, red fire indicator light; Fault alarm When the sensor, power supply and other anomalies are found, the detector enters into the fault alarm state; Fault output relay action, yellow fault indicator light; When the fire and failure occurred at the same time, the priority of the fire; Multistage adjustable alarm threshold (by bar set) Monitor the state each time the green light flashes to indicate the alarm threshold Alarm delay 0-30S adjustable (factory set to 0S) A combination model of hardware compensation and intelligent software compensation for drift compensation sensor Can effectively compensate for the temperature, environmental changes and components of the long-term work of drift Interference source suppression can effectively suppress the impact of non flame interference sources, such as the sun (direct and reflection), commonly used artificial light source, background Radiation source, heat moving objects, electric welding, etc. Indicator light L monitor status: green light L fire status: red light always light L fault status: yellow light is always bright output L fire alarm relay, alarm action, output contact 3A@125VAC 3A@30VDC L fault relay, fault time action, output contact 3A@125VAC 3A@30VDC L serial communication interface Environmental parameter Project specifications Operating temperature of -10 degrees C - +55 C or -40 -+70 Working humidity is less than or equal to 95%HR, no condensation Storage temperature -40 C +85 FLJD and FLJK Connection detector fault output contact, when the probe Failure or power supply failure When the contact is broken FRJD and FRJK connection detector fire alarm output contacts, when the When the alarm is measured, the contact is closed. 24V external power supply positive electrode GND external power supply negative electrode
$269.00The TX7300 Addressable Sounder Strobe is alarm warning device used to notify persons in the vicinity of the occurrence fire emergency in order the person to take appropriate measures. The unit adopt multi-application device starting from the types, parameters and wiring layout in single unit. The TX7300 can change into different alarm warning types such as sounder-strobe type, sounder type or strobe type using programming tool. In addition, parameters can be configured according to the requirement which include alarm tone from 17 different tones, single address or dual address mode and also setting of power mode to low current consumption in a simple programming.
The TX7140 Intelligent Manual Call point use a non-breakable glass which is designed to press under light pressure triggering the call point into an alarm condition, with LED indicator mounted onto the front face to simplify the location of an operated call point. Safe to press and no hammer is required. The protected flap on the lower part is used for reset through supplied special tool.
The fire alarm system programmer is used for TX brand addressable fire alarm control panel. With the programmer, the smoke detector, heat detector, gas sensor, manual fire alarm button, manual call point and input output module can be encoded with address. After all fire detectors are encoded, it can be installed on ceiling, wall of protected areas and warning areas. Each detector has unique address and when alarm occurs, from the displayer and alarm panel, the alarm point will be known immediately. You can easy program detectors with fire alarm system programmer.
Analogue sensor and digital addressing Provide real time algorithm to the control panel 360 degree visual indicator The TX7110 Intelligent Fixed and Rate of Rise Heat Detector is reliable for application in places where may have high dust level or smoky environments, making a normal smoke detector undesirable. The unit manufactured base on the sensitivity requirement of EN 54 part 5, European Standard. The unit is aesthetically pleasing with unobtrusive design that will complement modern building designs. The unit incorporates an intelligent processor that provides inbuilt A/D converter, and Self-Diagnosis and History log.
Addressable fire alarm system LPCB EAC certificate professional fire security equipment. Heat Detector LPCB CE EN54 works with TC-5109 Advanced single-chip microcomputer technology Non-polarized two-wire Indoor garage, kitchen, boiler room, generator room, drying room and other places Approvals:LPCB(EN54-5) CE Technical Specifications Operating voltage Loop 24V(18.5V~26V) Operating current Standby current: ≤0.3mA;Alarm current: ≤0.8mA Operating Environment Temperature: -10°C~+50°C;Relative Humidity: ≤95%, non-condensing Indicator Red,Flashes when polling,Illuminates in alarm Ingress protection rating IP33 Material and color of enclosure ABS; Milky white Coding method Electronically coding Code range 1~255 Weight About 110g Mounting hole distance 60mm Dimension 100mm×50mm (with base) Product installation manual and video at heat detector
$16.80Fire alarm siren works with TC series addressable fire alarm system TC-5109 LPCB alarm panel. LPCB certified addressablel horn strobe flash and sounder Installed in public places A kind of audio and visual alarm device used to warn people in field when fire occurs Four wires:non-polarized signal two-wire, and non-polarized DC24V power two-wire Built-in microprocessor Self-diagnostic function Electronically coding Approvals:LPCB(EN54-3) CE Technical Specifications Operating voltage Loop: 24V (16V~28V);Power: DC24V (DC19V~DC28V) Standby current Loop: ≤0.2mA;Power: ≤0.5mA Active current Loop: ≤1.5mA;Power: ≤50mA Operating Environment Indoor (Non-residential);Temperature: -10°C~+50°C; Relative Humidity: ≤95%(40±2°C) Sound level 80dB~115dB (A weighted) Pitch shift periodic 3.5S~4.5S Basic flashing frequency 1Hz~2Hz Weight 200g Dimension (L×W×H) 115mm×55.3mm×140mm Product installation manual and video can be found at fire horn
$18.50Addressable fire alarm system TC-5109 compatible Single I/O Module LPCB intelligent Module Designed to connect with linkage devices of fire alarm controlpanel, such as exhaust valve, air valve, fire damper etc., and can receive feedback signal from device Non-polarized two-wire Active and passive output The input terminal can be in field set to normally open detecting wire or self-feedback mode, which can be connected with passive contact Approvals:LPCB(EN54-18) CE Technical Specifications Operating voltage Loop:24V (18.5V~26V);Power: DC24V (DC19V~DC28V) Standby current Loop: ≤0.2mA;Power: ≤2mA Starting current Loop: ≤2mA;Power: ≤22mA Operating Environment Temperature: -10°C~+55°C;Relative Humidity: ≤95%, non-condensing Output capacity Passive:Capacity: DC30V/3A;Contact resistance in normal condition: 100kΩ;Closed when activated;Suitable for DC or AC12V~48V;Active output: DC24V/1.5A Indicator Red,Input indicator,Flashes when polling,Illuminates in action,Output indicator,Illuminates in action Coding method Electronically coding Code range 1~255 Material and color of enclosure ABS; Porcelain white Weight About 147g (with base) Mounting hole distance 60mm Dimension (L×W×H) 86mm×38mm×86mm (with base) Product installation manual and video at fire alarm module
$17.90EN54-7 Compliance Commercial Fire Alarm System. Using microprocessor technology with memory capacity up to 10 events The TX7100 Intelligent Addressable Optical Smoke Detector is the ideal device for most applications,due to its spiffing linear response to a wide variety of different types of smoke patterns. The unitmanufactured the sensitivity requirement of EN 54 part 7, European Standard. The unit is aesthetically pleasing with unobtrusive design that will complement modern building designs. The unit incorporates an intelligent processor that provides Algorithm map, inbuilt A/D converter, Drift compensation, and Self-Diagnosis and History log.