Back lit LED displaying all the information Display Capacity: Max 1024 pieces of scrolling information Simultaneous audible and visible alarming signals with the control panel MUTE, UP, DOWN and BROWSE operational keys are available
TX7201 Addressable Zone Monitor unit is an addressable interface module, which will integrate conventional detectors or conventional manual call points to addressable system. When any of the connected devices alarms are active, the unit can send the alarm message to fire alarm controller, which generates alarm signal and displays its address. The unit can match with the conventional optical smoke detector, conventional rate of rise and fixed temperature detector and conventional manual call point etc. It has the function of checking short or open circuit of the output connection, by the End of Line Resistor (EOLR). The fault massage includes open circuit, short circuit or any removal of the detectors.
TX7130 Conventional Reflective Beam Detector has built in Laser beam pointing and Digital guide display for real user friendly alignment method. The Laser beam pointing accurately point the exact location where to mount mirror and with additional digital guide display allows to monitor and guide on the actual light intensity between the mirror and detector which cannot be seen by our naked eye making it more easy and convenient in alignment commissioning. The TX7130 has four adjustable operational ranges of between 8 to 20, 20 to 40, 40 to 70 and 70 to 100 meters beside with three adjustable sensitivity setting ranges from 2.6dB, 3.8dB and 5.8dB to meet the specific environmental requirement. The TX7130 works on the principle of reflective infrared beam obscuration. Used in conjunction with a reflector, it will notify the fire alarm panel when the infrared beam is obscured by smoke. The TX7130 is ideal for use high ceiling and wide areas such as warehouses, large storages, shopping malls, leisure centers, exhibition halls, hotel lobbies, printing houses, garment factories, museums and prisons, as well as places where slight smoke particles or corrosive gas exist.
The TX7300 Addressable Sounder Strobe is alarm warning device used to notify persons in the vicinity of the occurrence fire emergency in order the person to take appropriate measures. The unit adopt multi-application device starting from the types, parameters and wiring layout in single unit. The TX7300 can change into different alarm warning types such as sounder-strobe type, sounder type or strobe type using programming tool. In addition, parameters can be configured according to the requirement which include alarm tone from 17 different tones, single address or dual address mode and also setting of power mode to low current consumption in a simple programming.
The TX7140 Intelligent Manual Call point use a non-breakable glass which is designed to press under light pressure triggering the call point into an alarm condition, with LED indicator mounted onto the front face to simplify the location of an operated call point. Safe to press and no hammer is required. The protected flap on the lower part is used for reset through supplied special tool.
The fire alarm system programmer is used for TX brand addressable fire alarm control panel. With the programmer, the smoke detector, heat detector, gas sensor, manual fire alarm button, manual call point and input output module can be encoded with address. After all fire detectors are encoded, it can be installed on ceiling, wall of protected areas and warning areas. Each detector has unique address and when alarm occurs, from the displayer and alarm panel, the alarm point will be known immediately. You can easy program detectors with fire alarm system programmer.
Analogue sensor and digital addressing Provide real time algorithm to the control panel 360 degree visual indicator The TX7110 Intelligent Fixed and Rate of Rise Heat Detector is reliable for application in places where may have high dust level or smoky environments, making a normal smoke detector undesirable. The unit manufactured base on the sensitivity requirement of EN 54 part 5, European Standard. The unit is aesthetically pleasing with unobtrusive design that will complement modern building designs. The unit incorporates an intelligent processor that provides inbuilt A/D converter, and Self-Diagnosis and History log.
EN54-7 Compliance Commercial Fire Alarm System. Using microprocessor technology with memory capacity up to 10 events The TX7100 Intelligent Addressable Optical Smoke Detector is the ideal device for most applications,due to its spiffing linear response to a wide variety of different types of smoke patterns. The unitmanufactured the sensitivity requirement of EN 54 part 7, European Standard. The unit is aesthetically pleasing with unobtrusive design that will complement modern building designs. The unit incorporates an intelligent processor that provides Algorithm map, inbuilt A/D converter, Drift compensation, and Self-Diagnosis and History log.
The TX7230 manufactured base on the requirement of EN 54 part 17, European Standard. In the event of short circuit on the detection loop the TX7230 Isolators either side of the loop will detect the problem and open circuit and isolates the faulty part of the loop, enabling other devises on the unaffected part of the loop to operate normally. The module will continue to monitor for the fault to be repaired, once the fault is cleared the isolator will automatically reinstate the effected part of the loop.
Alarm Control Panel is designed and manufactured to meet the requirement of BS EN54 Part 2&4. TX7004 comprise of a range of analogue addressable, microprocessor based fire alarm control equipment to offer flexibility in both design and operation. The System is modular concept for easy tailoring of system design, to meet the full requirements of the project. The TX7004 is designed to provide early warning fire detection, to quickly identify the location of fire and provide user definable text informing the occupants of the building of potential smoke spread. Simultaneously, the TX7004 will alert and evacuate the occupants, and control all necessary auxiliary command functions such as elevator control, air handling shut down, gas shut off & damper control, as per the cause and effects requirements configured though Command Builder Set-up The TX7004 modular construction panel, capable of supervising two monitored detection loops expandable up to four [4] loops on standalone basis. Each loop is capable to accommodate of 254 addressable devices of any combination with T&A protocols, namely intelligent sounder strobe TX7300 & intelligent sounder TX7320 complying with EN 54-3, rate of rise and fixed temperature heat detector TX7110 complying with EN 54-5, photoelectric smoke detector TX7100 complying with EN 54-7, intelligent manual call point TX7140 complying with EN 54-11, intelligent reflective beam detector (TX7130) complying with EN 54-12, input and output module TX7200, TX7210, TX7220 complying with EN54-18, and loop isolator TX7230 complying with EN 54-17. The T&A devices are fully loop powered to support saving cost of the cable. These systems incorporate a number of features to allow easy operation through a user-friendly menu. The TX7004 has a LCD touch screen and Keypad menus for alternative operation with large button access to operate the keypad control by fire brigade personnel providing total user-friendly interface for browsing and programming. Added the commission features such as colour coded loop mapping, dual address and device mismatch monitoring, one-man test, simplified command builder’s configuration that has proved to be highly rated by both commissioning and service engineers. The Control Panel has multiple built-in features. The loop card has built-in surge protection and the communication card interface support multiple interface protocol such as USB, Ethernet, CAN Bus, Serial, RS485, Fiber Optic in one singe card. The panel is Built-In Printer and 160 LED Zones Indicators. The panel provides variety of inputs and outputs interfaces and auxiliary such as Output to Sounder, F.P.E., Alarm and Fault output, Relays and Power Auxiliary. 1.2 Feature and Benefits • Compliance EN54-2 & N54-4 • Using advance microprocessor technology with Large memory capacity • Enhance user interface combining LCD Touch screen and keypad access • Support real time visual algorithm • Enhance false alarm prevention • Keypad and PC programming • Support Multiple interface protocol such as USB/Ethernet/Can Bus/Serial/RS485/Fiber Optic • Support Loop Powered devices for extra saving on cable cost • Built-In Printer and 160 LED Zones Indicators Commissioning Advantage • Auto Enrolling of Devices • Loop Mapping with colour coding status • Monitor device mismatch and dual address conflict • Command Builder to create requirements for fire event scenario • With Loop protection against power surge • One-man test with On/Off sounder • Programming Protection System Capacity • Up to 4 loop • Support 254 Devices/One loop (1,016 ideal) • Network up to 512 Node • Programmable Capacity • Zones up to 3000 • Sounders Groups 1-1000 • Other Groups 1001- 2000 • Built-in 160 LED Zones Indicator 1.4 Technical Specification • Compliance EN54-2 & 4 • Input Voltage 230VAC +10%-15%, 50Hz (120VAC, 60Hz, it is not applicable for EN54 & Not tested by LPCB) • Input Current Consumption 1A • PSU Output To CIE 21.5~28.5VDC • Batteries Maximum Charge Capacity: 2 x 12V / 28AH Maximum Charge Current: 1.2A I maxA: 0.93A I maxB: 2.53A Minimum Quiescent Current: 0.45A(Imin) Maximum Internal Resistance: 1.0Ω Rechargeable-Lead acid type battery • Recommended manufacturer and model of battery: PS-12280 12V28AH (Tested With CIE By LPCB) • Networking and Interfaces Panel to panel communication Can Bus [loop] Number of Panels 512 Interface Port USB, RS485 Serial, RS232 Serial, Ethernet • System Capacity Memory [Non-Volatile] 1000 Fire Events, 10,000 General Event Zones 3,000 programmable Total Group 3,000 programmable Sounder Group 1,000 programmable Common Group 2,000 programmable • Loop Specifications Protocol/Addressing T&A, Value range from 1 to 254 No. of Loop 4 Loop Protection Built-in 4kV Surge protection Power rating 16~24Vdc /120mA Cabling 1.0Km Max Length/2 x 1.5mm²solid core Fire resistance • Recommended Wiring (subject to local installation codes) ISST-SFR3/ 711c-(cl-5) Intelligent Safety & Security Technology Limited NoBurn XPS/ 682e/01 Ventcroft Limited FT30 SAFFIRE/ 1134j Draka UK Limited Context Plus/682a-(cl-3) Context Plus Ltd FP200 Gold LSOH/ 077k/01 Prysmian Cables & Systems Limited And all LPCB approved Fire cables Recommended Cable Length ≤1000m • Panel Input/outputs Programmable Relays 4 circuits: Normally Open/Close Programmable Input 1 Circuit: Current Limited 24Vdc (for future use) Programmable Auxiliary Power 19~28Vdc (Current Limited) Fixed Outputs (FPE/Sounder) 2 Circuits: 18~28Vdc (Current Limited) • Indicator 24 LED Status/ 160 Zone Indicators • Display 7” TFT Touch Screen • Keypad 5 Brigade buttons and Programming Keypad • Material / Color Flat sheet Metal / with outer glass door, Orange stripe • Dimension Lx W x H 530 mm x 490 mm x 135 mm • Weight 16.70 Kg • Temperature -5℃~+40℃ • Humidity 0 to 95% Relative Humidity, Non condensing
Addressable fire alarm system LPCB EAC certificate professional fire security equipment. Heat Detector LPCB CE EN54 works with TC-5109 Advanced single-chip microcomputer technology Non-polarized two-wire Indoor garage, kitchen, boiler room, generator room, drying room and other places Approvals:LPCB(EN54-5) CE Technical Specifications Operating voltage Loop 24V(18.5V~26V) Operating current Standby current: ≤0.3mA;Alarm current: ≤0.8mA Operating Environment Temperature: -10°C~+50°C;Relative Humidity: ≤95%, non-condensing Indicator Red,Flashes when polling,Illuminates in alarm Ingress protection rating IP33 Material and color of enclosure ABS; Milky white Coding method Electronically coding Code range 1~255 Weight About 110g Mounting hole distance 60mm Dimension 100mm×50mm (with base) Product installation manual and video at heat detector
$16.80DC24V LPCB Approved Addressable fire alarm button ressetable manual fire alarm call point works with TC series addressable fire alarm system. Installed in public places; when there is a fire, pressing the frangible element on this MCP can send fire signal to fire alarm control panel Alarm by pressing, reset by a special key Non-polarized two-wire to the control panel Reusable Approvals:LPCB(EN54-7) CE Technical Specifications Operating voltage Loop 24V(18.5V~26V) Operating current Standby current: ≤0.2mA;Alarm current: ≤0.8mA Operating Environment Indoor Temperature: -10°C~+55°C;Relative Humidity: ≤95%, non-condensing Indicator Red. Flashes about every 3s when polling;Illuminates after in alarm Coding method Electronically coding Code range 1~255 Material and color of enclosure ABS; Red Weight About 120g (with base) Mounting hole distance 60mm Dimension (L×W×H) 95mm×44mm×95mm (with base) Product installation manual and video atalarm button
$16.80LPCB Approved Intelligent smoke detector Addressable fire alarm system works with TC series addressable fire alarm system LPCB TC-5109 alarm panel fire fighting Infrared scattering principle Non-polarized two-wire Drift compensation and fault detecting function Reporting dirt fault Hotel, restaurant, warehouse, library, office building, teaching building, power plant and other places Approvals:LPCB(EN54-7) CE Technical Specifications Operating voltage Loop 24V(18.5V~26V) Operating current Standby current: ≤0.3mA;Alarm current: ≤0.8mA Operating Environment Temperature: -10°C~+55°C,Relative Humidity: ≤95%, non-condensing Indicator Red,Flashes when polling,Illuminates in alarm Ingress protection rating IP23 Material and color of enclosure ABS; Milky white Coding method Electronically coding Code range 1~255 Weight About 110g Mounting hole distance 60mm Dimension 100mm×51mm (with base) Product installation manual and video at smoke detector
$16.80Addressable fire alarm system TC-5109 compatible Single I/O Module LPCB intelligent Module Designed to connect with linkage devices of fire alarm controlpanel, such as exhaust valve, air valve, fire damper etc., and can receive feedback signal from device Non-polarized two-wire Active and passive output The input terminal can be in field set to normally open detecting wire or self-feedback mode, which can be connected with passive contact Approvals:LPCB(EN54-18) CE Technical Specifications Operating voltage Loop:24V (18.5V~26V);Power: DC24V (DC19V~DC28V) Standby current Loop: ≤0.2mA;Power: ≤2mA Starting current Loop: ≤2mA;Power: ≤22mA Operating Environment Temperature: -10°C~+55°C;Relative Humidity: ≤95%, non-condensing Output capacity Passive:Capacity: DC30V/3A;Contact resistance in normal condition: 100kΩ;Closed when activated;Suitable for DC or AC12V~48V;Active output: DC24V/1.5A Indicator Red,Input indicator,Flashes when polling,Illuminates in action,Output indicator,Illuminates in action Coding method Electronically coding Code range 1~255 Material and color of enclosure ABS; Porcelain white Weight About 147g (with base) Mounting hole distance 60mm Dimension (L×W×H) 86mm×38mm×86mm (with base) Product installation manual and video at fire alarm module
$17.90Fire alarm siren works with TC series addressable fire alarm system TC-5109 LPCB alarm panel. LPCB certified addressablel horn strobe flash and sounder Installed in public places A kind of audio and visual alarm device used to warn people in field when fire occurs Four wires:non-polarized signal two-wire, and non-polarized DC24V power two-wire Built-in microprocessor Self-diagnostic function Electronically coding Approvals:LPCB(EN54-3) CE Technical Specifications Operating voltage Loop: 24V (16V~28V);Power: DC24V (DC19V~DC28V) Standby current Loop: ≤0.2mA;Power: ≤0.5mA Active current Loop: ≤1.5mA;Power: ≤50mA Operating Environment Indoor (Non-residential);Temperature: -10°C~+50°C; Relative Humidity: ≤95%(40±2°C) Sound level 80dB~115dB (A weighted) Pitch shift periodic 3.5S~4.5S Basic flashing frequency 1Hz~2Hz Weight 200g Dimension (L×W×H) 115mm×55.3mm×140mm Product installation manual and video can be found at fire horn
$18.50TC5402W wireless heat detector is an intelligent household fire detector with high- precision thermostor as the sensor, which can be used together with the wireless fire alarm control panel. The detector uses advanced wireless transceiver technology and high-integration micro-processing chip to process data. Technical Data All data is supplied subject to change without notice. Specifications are typical at 24V, 25℃ and 50% RH unless otherwise stated. Battery CR17450 3V Operating current monitoring current≤3uA , alarm current≤18mA Coding method automatically assigned when networking Radio frequency transmit power<20dBm Frequency band 470MHz Communication distance ≤500m Communication method 470MHz FSK coded bidirectional Operating environment temperature 10℃~+55℃ relative humidity ≤95% Dimension 100mm*54mm(with base) Weight 110g Using advanced wireless transceiver technology, signal transmission can be completed without wiring, and the project is simple and convenient. It adopts 470MHz communication and FSK coding technology, which has strong anti- interference ability and long transmission distance Low-voltage battery detection, reminding the user to replace the battery when it is insufficient to maintain the normal operation of the detector.
$22.50TCSB5406W wireless manual call point is suitable for installation in public places, factories and other environments. When a fire is manually confirmed, press the button, and the red light of the MCP is always on, so that an alarm signal can be sent to the control panel through wireless communication technology. When the control panel responds to the alarm signal, the MCP enters a state of waiting for the control panel to reset, and the control panel displays the coded information of the MCP and gives an alarm sound. You can set mobile phone for the fire alarm, watch video at https://www.youtube.com/shorts/_OUV9_ZrYX4 Technical Data All data is supplied subject to change without notice. Specifications are typical at 24V, 25℃ and 50% RH unless otherwise stated. Battery CR17450 3V Voltage range 2.7~3.3V Operating current monitoring current≤10uA , alarm current≤19mA Coding method automatically assigned when networking Radio frequency transmit power<20dBm Frequency band 470MHz Communication distance ≤500m Operating environment temperature 10℃~+55℃ relative humidity ≤95% Dimension 95mm*96mm*50mm Weight 190g Push-type structure design is adopted, and special tools are required to reset after pressing MCP; Using 470MHz wireless communication technology, there is no need to embed wiring, and the engineering installation is convenient and fast; with battery low voltage detection function, which can reflect the battery power situation in time; Using microprocessor to realize signal processing, communicating with controller by digital signal, it works stably and reliably, and has good ability to suppress electromagnetic interference.
$22.50JTY-GM-TC5401W wireless photoelectric smoke detector is an intelligent industrial fire detector based on the principle of transmitting and receiving high- precision infrared tubes, which can be used with the wireless fire alarm control panel and smart home platform APP The detector uses 470MHz wireless transceiver technology to process data with a highly integrated micro-processing chip. It has the characteristics of high sensitivity, long transmission distance and low power consumption. Technical Data: All data is supplied subject to change without notice. Specifications are typical at 24V, 25℃ and 50% RH unless otherwise stated. Battery CR17450 3V Operating current monitoring current≤8uA , alarm current≤18mA Coding method: automatically assigned when networking Radio frequency transmit power<20dBm Frequency band 470MHz Communication distance ≤500m Communication method 470MHz FSK coded bidirectional Protection area 20~30m2 Operating environment temperature 10℃~+55℃ relative humidity ≤95% Dimension 100mm*55mm(with base) Weight 118g accurately and quickly detect the change of smoke concentration in the environment, accurately and timely determine the fire and give an alarm advanced wireless communication technology, signal transmission can be completed without wiring, and engineering installation is simple and convenient It has the function of battery low voltage detection, and reminds the user to replace the battery when it is insufficient to maintain the normal operation of the detector.
$22.50