TC5402W wireless heat detector is an intelligent household fire detector with high- precision thermostor as the sensor, which can be used together with the wireless fire alarm control panel. The detector uses advanced wireless transceiver technology and high-integration micro-processing chip to process data. Technical Data All data is supplied subject to change without notice. Specifications are typical at 24V, 25℃ and 50% RH unless otherwise stated. Battery CR17450 3V Operating current monitoring current≤3uA , alarm current≤18mA Coding method automatically assigned when networking Radio frequency transmit power<20dBm Frequency band 470MHz Communication distance ≤500m Communication method 470MHz FSK coded bidirectional Operating environment temperature 10℃~+55℃ relative humidity ≤95% Dimension 100mm*54mm(with base) Weight 110g Using advanced wireless transceiver technology, signal transmission can be completed without wiring, and the project is simple and convenient. It adopts 470MHz communication and FSK coding technology, which has strong anti- interference ability and long transmission distance Low-voltage battery detection, reminding the user to replace the battery when it is insufficient to maintain the normal operation of the detector.
$22.50Back lit LED displaying all the information Display Capacity: Max 1024 pieces of scrolling information Simultaneous audible and visible alarming signals with the control panel MUTE, UP, DOWN and BROWSE operational keys are available
The fire alarm system programmer is used for TX brand addressable fire alarm control panel. With the programmer, the smoke detector, heat detector, gas sensor, manual fire alarm button, manual call point and input output module can be encoded with address. After all fire detectors are encoded, it can be installed on ceiling, wall of protected areas and warning areas. Each detector has unique address and when alarm occurs, from the displayer and alarm panel, the alarm point will be known immediately. You can easy program detectors with fire alarm system programmer.
Addressable fire alarm system LPCB EAC certificate professional fire security equipment. Heat Detector LPCB CE EN54 works with TC-5109 Advanced single-chip microcomputer technology Non-polarized two-wire Indoor garage, kitchen, boiler room, generator room, drying room and other places Approvals:LPCB(EN54-5) CE Technical Specifications Operating voltage Loop 24V(18.5V~26V) Operating current Standby current: ≤0.3mA;Alarm current: ≤0.8mA Operating Environment Temperature: -10°C~+50°C;Relative Humidity: ≤95%, non-condensing Indicator Red,Flashes when polling,Illuminates in alarm Ingress protection rating IP33 Material and color of enclosure ABS; Milky white Coding method Electronically coding Code range 1~255 Weight About 110g Mounting hole distance 60mm Dimension 100mm×50mm (with base) Product installation manual and video at heat detector
$16.80Electrical fire monitoring system residual current detector. Built-in processor can receive the signal from transformer and handle those signal into two forms as normality and alarming, both of which will be transmitted to the electrical fire monitoring equipment. The microprocessor will transmit the mode status of normality or alarming to monitoring devices. How to use electric fire monitor equipment and how to install? Technical Features 1. Operating Voltage: Pulse voltage of circuit loop: Loop 24V Available range: 16V~30V 2. Operating current: Standby current≤0.4mA Alarming current≤0.7mA 3. Rated alarming current: 200mA~1000mA, step-size 1mA 4. Encoding mode: electrical addressable mode. It takes one site on the loop. And an addressable code could be any in the range of 1~255. 5. Cabling: connecting with the monitoring devices through signal nonpolar two-line loop. 6. Aperture of wires: 93mm 7. Rated operating current of main loop: less than 630A. 8. Rated frequency of wires: 50Hz/60Hz 9. Ambient environment: Temperature: -10℃~+55℃ Relative humidity≤95%, non-condensing 10. Dimension: 188mm × 145mm × 45mm 11. Enclosure material: ABS plastic 12. Ingress Protection Rating: IP30 13. Weight: about 1.3kg
$55.00TCSG5416W wireless sounder strobe is suitable for installation in public places, factories and other environments, and is used together with JB-TB- TC5126W wireless fire alarm control panel. When the control panel receives the fire alarm instructions from other fire alarm devices, the control panel starts the alarm through wireless signals, and the alarm sends out sound and light signals to achieve the purpose of audible and visual alarm. Technical Data All data is supplied subject to change without notice. Specifications are typical at 24V, 25℃ and 50% RH unless otherwise stated. Battery CR17450-2-080-02 Rated Operating Voltage DC3V Operating current monitoring current≤45uA , alarm current≤240mA Sound level 75dB~115dB Coding method automatically assigned when networking Radio frequency transmit power<20dBm Communication method 470MHz FSK coded bidirectional Communication distance ≤500m Operating environment temperature 10℃~+55℃ relative humidity ≤95% Dimension 101mm*137mm*43mm Weight 170g The 470MHz wireless communication technology is adopted, and no embedded wiring is needed, so the engineering installation is convenient and quick; With battery low voltage detection function, it can reflect the battery power situation in time; The microprocessor is used to realize signal processing, and the digital signal is used to communicate with the control panel, which works stabely and reliably, and has a good ability to suppress electromagnetic interference.
$38.00Residual Current Electrical Fire Monitoring Detector TC-DH01B-J225 Through-line aperture: 225 × 56mm main circuit rated operating current: less than 630A Dimensions: 296mm × 166mm × 45mm Standard: GB14287.2-2014 "Electric Fire Monitoring Systems - Part 2: Residual Current Electric Fire Detectors” The Detector builds up an electrical fire monitoring system with our productions of JB-DH-TC5600 Electrical Fire Monitoring Equipment, TC-DH12A Combined Electrical Fire Monitoring Detector and TC-DH230 Combined Electrical Fire Monitoring Detector. The Detector can realize the function of leakage test, temperature test and output controlling by connecting with JB-DH-TC5600 Electrical Fire Monitoring Equipment through two-line loops. It can also connect with many other kinds of residual current transformers to realize stable and reliable operating. Electrical fire monitoring system can effectively prevent electrical fires and reduce losses. Technical Specifications: 1. Operating Voltage: Pulse voltage of circuit loop: Loop 24V Available range: 16V~30V 2. Operating current: Standby current≤0.4mA Alarming current≤0.7mA 3. Rated alarming current: 200mA~1000mA, step-size 1mA 4. Encoding mode: electrical addressable mode. It takes one site on the loop. And an addressable code could be any in the range of 1~255. 5. Cabling: connecting with the monitoring devices through signal nonpolar two-line loop. 6. Aperture of wires: 225mm×56mm 7. Rated operating current of main loop: less than 630A. 8. Rated frequency of wires: 50Hz/60Hz 9. Ambient environment: Temperature: -10℃~+55℃ Relative humidity≤95%, non-condensing 10. Dimension: 296mm×166mm×45mm 11. Enclosure material: ABS plastic 12. Ingress Protection Rating: IP30 13. Weight: about 3kg
$60.00Addressable fire alarm system TC-5109 compatible Single I/O Module LPCB intelligent Module Designed to connect with linkage devices of fire alarm controlpanel, such as exhaust valve, air valve, fire damper etc., and can receive feedback signal from device Non-polarized two-wire Active and passive output The input terminal can be in field set to normally open detecting wire or self-feedback mode, which can be connected with passive contact Approvals:LPCB(EN54-18) CE Technical Specifications Operating voltage Loop:24V (18.5V~26V);Power: DC24V (DC19V~DC28V) Standby current Loop: ≤0.2mA;Power: ≤2mA Starting current Loop: ≤2mA;Power: ≤22mA Operating Environment Temperature: -10°C~+55°C;Relative Humidity: ≤95%, non-condensing Output capacity Passive:Capacity: DC30V/3A;Contact resistance in normal condition: 100kΩ;Closed when activated;Suitable for DC or AC12V~48V;Active output: DC24V/1.5A Indicator Red,Input indicator,Flashes when polling,Illuminates in action,Output indicator,Illuminates in action Coding method Electronically coding Code range 1~255 Material and color of enclosure ABS; Porcelain white Weight About 147g (with base) Mounting hole distance 60mm Dimension (L×W×H) 86mm×38mm×86mm (with base) Product installation manual and video at fire alarm module
$17.90The TX7230 manufactured base on the requirement of EN 54 part 17, European Standard. In the event of short circuit on the detection loop the TX7230 Isolators either side of the loop will detect the problem and open circuit and isolates the faulty part of the loop, enabling other devises on the unaffected part of the loop to operate normally. The module will continue to monitor for the fault to be repaired, once the fault is cleared the isolator will automatically reinstate the effected part of the loop.
TCXH5415W wireless fire hydrant button is suitable for installation in public places. when manually confirming to start the fire pump, press the start button on the fire hydrant button, and the red light of the fire hydrant button is always on, which can send a start signal to the control panel through wireless communication technology and start the fire pump at the same time; After the fire pump has been started, the fire hydrant button answer light is always on, the fire hydrant button sends an answer signal to the control panel through wireless communication technology, and the fire hydrant button enters the state of waiting for the control panel to reset. The control panel can display the coded information of hydrant button and make sound. Technical Data All data is supplied subject to change without notice. Specifications are typical at 24V, 25℃ and 50% RH unless otherwise stated. Battery CR17450 Rated Operating Voltage 3V Operating current monitoring current≤15uA , alarm current≤10mA Coding method automatically assigned when networking Radio frequency transmit power<20dBm Communication distance ≤500m Communication method 470MHz FSK coded bidirectional Operating environment temperature 10℃~+55℃ relative humidity ≤95% Dimension 96mm*95mm*50mm Weight 190g The 470MHz wireless communication technology is adopted, and no embedded wiring is needed, so the engineering installation is convenient and quick; With battery low voltage detection function, it can reflect the battery power situation in time; The microprocessor is used to realize signal processing, and the digital signal is used to communicate with the control panel, which works stable and reliably, and has a good ability to suppress electromagnetic interference.
$26.50Residual Current Transformer TC-DH01B-J325 Through-line aperture: 325 × 60mm main circuit rated operating current: less than 1000A Dimensions: 445mm × 220mm × 60mm Connected to the monitoring device JB-DH-TC5600 with a non-polar two buses, while achieving communication and power supply functions The address code is electronically encoded and can be written in advance by the electronic encoder. The engineering debugging is simple and reliable The microprocessor monitors the operation and transmits the status of the module to the monitoring device in both normal and alarm modes Wire system: non-polar connection to the signal bus of the monitoring device Residual current detector Specification: 1. Operating Voltage: Pulse voltage of circuit loop: Loop 24V Available range: 16V~30V 2. Operating current: Standby current≤0.4mA Alarming current≤0.7mA 3. Rated alarming current: 200mA~1000mA, step-size 1mA 4. Encoding mode: electrical addressable mode. It takes one site on the loop. And an addressable code could be any in the range of 1~255. 5. Cabling: connecting with the monitoring devices through signal nonpolar two-line loop. 6. Aperture of wires: 325mm×60mm 7. Rated operating current of main loop: less than 1000A. 8. Rated frequency of wires: 50Hz/60Hz 9. Ambient environment: Temperature: -10℃~+55℃ Relative humidity≤95%, non-condensing 10. Dimension: 445mm×220mm×60mm 11. Enclosure material: ABS plastic 12. Ingress Protection Rating: IP30 13. Weight: about 8kg
$120.00EN54-7 Compliance Commercial Fire Alarm System. Using microprocessor technology with memory capacity up to 10 events The TX7100 Intelligent Addressable Optical Smoke Detector is the ideal device for most applications,due to its spiffing linear response to a wide variety of different types of smoke patterns. The unitmanufactured the sensitivity requirement of EN 54 part 7, European Standard. The unit is aesthetically pleasing with unobtrusive design that will complement modern building designs. The unit incorporates an intelligent processor that provides Algorithm map, inbuilt A/D converter, Drift compensation, and Self-Diagnosis and History log.
TCMK5411W wireless input module is suitable for installation in public places, factories and other environments. When there is a fire alarm, the module will send an alarm signal to the control panel through wireless communication technology after receiving the input signal specified by the manufacturer, and the red light is always on. Technical Data All data is supplied subject to change without notice. Specifications are typical at 24V, 25℃ and 50% RH unless otherwise stated. Battery CR17450 Rated Operating Voltage 3V Operating current monitoring current≤13uA , alarm current≤20mA Coding method automatically assigned when networking Radio frequency transmit power<20dBm Communication method 470MHz FSK coded bidirectional Communication distance ≤500m Operating environment temperature 10℃~+55℃ relative humidity ≤95% Dimension 101mm*137mm*43mm Weight 160g The 470MHz wireless communication technology is adopted, and no embedded wiring is needed, so the engineering installation is convenient and quick; With battery low voltage detection function, it can reflect the battery power situation in time; The microprocessor is used to realize signal processing, and the digital signal is used to communicate with the control panel, which works stable and reliably, and has a good ability to suppress electromagnetic interference.
$25.50Fire alarm siren works with TC series addressable fire alarm system TC-5109 LPCB alarm panel. LPCB certified addressablel horn strobe flash and sounder Installed in public places A kind of audio and visual alarm device used to warn people in field when fire occurs Four wires:non-polarized signal two-wire, and non-polarized DC24V power two-wire Built-in microprocessor Self-diagnostic function Electronically coding Approvals:LPCB(EN54-3) CE Technical Specifications Operating voltage Loop: 24V (16V~28V);Power: DC24V (DC19V~DC28V) Standby current Loop: ≤0.2mA;Power: ≤0.5mA Active current Loop: ≤1.5mA;Power: ≤50mA Operating Environment Indoor (Non-residential);Temperature: -10°C~+50°C; Relative Humidity: ≤95%(40±2°C) Sound level 80dB~115dB (A weighted) Pitch shift periodic 3.5S~4.5S Basic flashing frequency 1Hz~2Hz Weight 200g Dimension (L×W×H) 115mm×55.3mm×140mm Product installation manual and video can be found at fire horn
$18.50TC-ZJ402 The wireless signal extender is suitable for home wireless alarm system and industrial wireless alarm system. The repeater uses advanced wireless transceiver technology, built-in efficient anti-collision algorithm, and can set filtering rules, so that the repeater can work reliably in the system. At the same time, the repeater supports multiple groups of channels, so that the repeater can work in complex environments and in the presence of multiple hosts, realizing mutual non-interference, truly avoiding the collision of channels, and greatly improving the coverage of wireless networks. Technical Data All data is supplied subject to change without notice. Specifications are typical at 24V, 25℃ and 50% RH unless otherwise stated. Main power DC5V(Power Adapter) Standby power 3V/2400MAh Power consumption monitoring≤9W , alarm≤2.2W Operation indicator flash when normal Fault indicator on when standby power fails Communication indicator flash when forwarding info Wireless transmission power 19dBm Communication distance ≤500m Communication method 470MHz FSK coded bidirectional Operating environment temperature 10℃~+55℃ relative humidity ≤95% Dimension 130mm in diameter H:48mm Avoid excessive humidity in repeater installation position To ensure the long-term reliability and accuracy of the repeater, the wireless performance should be checked regularly. The free warranty period of this repeater is one year, with lifetime maintenance.
$35.50The detector can work independently or connect with JB-DH-TC5600 electrical fire monitoring equipment through two bus circuits, and realize the functions of leakage detection, temperature detection and output control. It works stably and reliably, and is connected with a variety of residual current transformers according to the magnitude of the over-line current. How to install electric fire monitoring system? Features 1.The Detector and the Electrical Fire Monitoring Equipment use non-polarized two-line system to connect. With mature technology, it is reliable in communication and convenient in cabling. 2. The Detector uses a high-performance CPU, intelligent algorithm and watchdog technology, highly efficient and reliable. 3. The Detector has a built-in passive output control which can connect with one or two loops to alarm leakage. 4. The Detector has the function of self-test which can test the screen and squealers working normally or not. 5. The Detector can set the residual current from 200mA to 1000mA of residual current transformers, which is high- precision detecting and widely used. It can be programmed with address and convenient for commission and maintenance. 6. The alarming temperature can be set from 45℃ to 140℃, high-precision detecting and widely used. It is convenient for commission and maintenance by the setup of addressable code and temperature. 7. The Detector has a good-looking appearance with intuitive showing of LCD information, simple operation and powerful functions, scalability and easy to installation. Technical Specification 1. Operating voltage: AC 220V 2. Operating current: ≤10mA 3. Alarming current: ≤25mA 4. Rated alarming current: 200mA~1000mA, step 1mA 5. Rated alarming temperature: 45℃-140℃, step 1℃ 6. Loop interface: Loop 24V, non-polarized 7. Capability of output terminal: 1A/AC125V,3A/DC24V 8. Response time: ≤10s 9. Rated frequency through the line: 50Hz/60Hz 10. The parameters of residual current transformer can be seen in chapter 5.3 11. Operating environment: Temperature: -10℃~+50℃ Relative Humidity: ≤95%, no condensation Altitude: <5000m 12. IP Grade: IP30 13. Weight: about 420g 14. Standard: GB 14287.2-2014“Electrical fire control system - Part 2: residual current electric fire detectors” GB 14287.3-2014“Electrical fire monitoring systems -Part 3: The temperature electric fire detectors” 4. Structure and Working Principle: 1. Refers to Fig.1 for the appearance of detector 2. Working principle The Detector receives the information from the sensor. When the information sent by the sensor reaches the setup value of threshold, the detector will send audible and visual alarm, and the screen will display the current alarm at the same time. If the Detector has been connect with the loop, the detector can upload alarm, faults and some other information to the electrical fire monitoring equipment and execute the order of the equipment.
$160.00TCMK5413W wireless input/output module is suitable for installation in public places, factories and other environments. When there is a fire alarm, the module can not only send an alarm signal to the control panel through wireless communication technology after receiving the closing signal, but also output the closing signal for connection with other equipment. Technical Data All data is supplied subject to change without notice. Specifications are typical at 24V, 25℃ and 50% RH unless otherwise stated. Battery CR17450 Rated Operating Voltage 3V Operating current monitoring current≤14uA , alarm current≤10mA Coding method automatically assigned when networking Radio frequency transmit power<20dBm Communication method 470MHz FSK coded bidirectional Communication distance ≤500m Operating environment temperature 10℃~+55℃ relative humidity ≤95% Dimension 101mm*137mm*43mm Weight 170g The 470MHz wireless communication technology is adopted, and no embedded wiring is needed, so the engineering installation is convenient and quick; With battery low voltage detection function, it can reflect the battery power situation in time; The microprocessor is used to realize signal processing, and the digital signal is used to communicate with the control panel, which works stable and reliably, and has a good ability to suppress electromagnetic interference.
$28.50Alarm Control Panel is designed and manufactured to meet the requirement of BS EN54 Part 2&4. TX7004 comprise of a range of analogue addressable, microprocessor based fire alarm control equipment to offer flexibility in both design and operation. The System is modular concept for easy tailoring of system design, to meet the full requirements of the project. The TX7004 is designed to provide early warning fire detection, to quickly identify the location of fire and provide user definable text informing the occupants of the building of potential smoke spread. Simultaneously, the TX7004 will alert and evacuate the occupants, and control all necessary auxiliary command functions such as elevator control, air handling shut down, gas shut off & damper control, as per the cause and effects requirements configured though Command Builder Set-up The TX7004 modular construction panel, capable of supervising two monitored detection loops expandable up to four [4] loops on standalone basis. Each loop is capable to accommodate of 254 addressable devices of any combination with T&A protocols, namely intelligent sounder strobe TX7300 & intelligent sounder TX7320 complying with EN 54-3, rate of rise and fixed temperature heat detector TX7110 complying with EN 54-5, photoelectric smoke detector TX7100 complying with EN 54-7, intelligent manual call point TX7140 complying with EN 54-11, intelligent reflective beam detector (TX7130) complying with EN 54-12, input and output module TX7200, TX7210, TX7220 complying with EN54-18, and loop isolator TX7230 complying with EN 54-17. The T&A devices are fully loop powered to support saving cost of the cable. These systems incorporate a number of features to allow easy operation through a user-friendly menu. The TX7004 has a LCD touch screen and Keypad menus for alternative operation with large button access to operate the keypad control by fire brigade personnel providing total user-friendly interface for browsing and programming. Added the commission features such as colour coded loop mapping, dual address and device mismatch monitoring, one-man test, simplified command builder’s configuration that has proved to be highly rated by both commissioning and service engineers. The Control Panel has multiple built-in features. The loop card has built-in surge protection and the communication card interface support multiple interface protocol such as USB, Ethernet, CAN Bus, Serial, RS485, Fiber Optic in one singe card. The panel is Built-In Printer and 160 LED Zones Indicators. The panel provides variety of inputs and outputs interfaces and auxiliary such as Output to Sounder, F.P.E., Alarm and Fault output, Relays and Power Auxiliary. 1.2 Feature and Benefits • Compliance EN54-2 & N54-4 • Using advance microprocessor technology with Large memory capacity • Enhance user interface combining LCD Touch screen and keypad access • Support real time visual algorithm • Enhance false alarm prevention • Keypad and PC programming • Support Multiple interface protocol such as USB/Ethernet/Can Bus/Serial/RS485/Fiber Optic • Support Loop Powered devices for extra saving on cable cost • Built-In Printer and 160 LED Zones Indicators Commissioning Advantage • Auto Enrolling of Devices • Loop Mapping with colour coding status • Monitor device mismatch and dual address conflict • Command Builder to create requirements for fire event scenario • With Loop protection against power surge • One-man test with On/Off sounder • Programming Protection System Capacity • Up to 4 loop • Support 254 Devices/One loop (1,016 ideal) • Network up to 512 Node • Programmable Capacity • Zones up to 3000 • Sounders Groups 1-1000 • Other Groups 1001- 2000 • Built-in 160 LED Zones Indicator 1.4 Technical Specification • Compliance EN54-2 & 4 • Input Voltage 230VAC +10%-15%, 50Hz (120VAC, 60Hz, it is not applicable for EN54 & Not tested by LPCB) • Input Current Consumption 1A • PSU Output To CIE 21.5~28.5VDC • Batteries Maximum Charge Capacity: 2 x 12V / 28AH Maximum Charge Current: 1.2A I maxA: 0.93A I maxB: 2.53A Minimum Quiescent Current: 0.45A(Imin) Maximum Internal Resistance: 1.0Ω Rechargeable-Lead acid type battery • Recommended manufacturer and model of battery: PS-12280 12V28AH (Tested With CIE By LPCB) • Networking and Interfaces Panel to panel communication Can Bus [loop] Number of Panels 512 Interface Port USB, RS485 Serial, RS232 Serial, Ethernet • System Capacity Memory [Non-Volatile] 1000 Fire Events, 10,000 General Event Zones 3,000 programmable Total Group 3,000 programmable Sounder Group 1,000 programmable Common Group 2,000 programmable • Loop Specifications Protocol/Addressing T&A, Value range from 1 to 254 No. of Loop 4 Loop Protection Built-in 4kV Surge protection Power rating 16~24Vdc /120mA Cabling 1.0Km Max Length/2 x 1.5mm²solid core Fire resistance • Recommended Wiring (subject to local installation codes) ISST-SFR3/ 711c-(cl-5) Intelligent Safety & Security Technology Limited NoBurn XPS/ 682e/01 Ventcroft Limited FT30 SAFFIRE/ 1134j Draka UK Limited Context Plus/682a-(cl-3) Context Plus Ltd FP200 Gold LSOH/ 077k/01 Prysmian Cables & Systems Limited And all LPCB approved Fire cables Recommended Cable Length ≤1000m • Panel Input/outputs Programmable Relays 4 circuits: Normally Open/Close Programmable Input 1 Circuit: Current Limited 24Vdc (for future use) Programmable Auxiliary Power 19~28Vdc (Current Limited) Fixed Outputs (FPE/Sounder) 2 Circuits: 18~28Vdc (Current Limited) • Indicator 24 LED Status/ 160 Zone Indicators • Display 7” TFT Touch Screen • Keypad 5 Brigade buttons and Programming Keypad • Material / Color Flat sheet Metal / with outer glass door, Orange stripe • Dimension Lx W x H 530 mm x 490 mm x 135 mm • Weight 16.70 Kg • Temperature -5℃~+40℃ • Humidity 0 to 95% Relative Humidity, Non condensing