Conventional fire alarm system remote LED flash lighting alarm The device is remote LED uses a state of-the-art designs. This LED is designed to be used with detectors. One 8mm LED provide local 360° visible alarm indication. They flash with the same as detector that be connected. Complete fire alarm system category and installation instruction manual can be downloaded at conventional fire alarm Features and Benefits Compatible with all the conventional fire alarm control panel 8mm Big Size LED Outside two holes provide 83mm(USA) Inner two holes provide 59mm(Europe) Wiring Terminals provided on the PCB board Technical Specifications Dimension: 102X86mm Height (including mounting base): 32 mm Weight: 50 g Operating Temperature Range: -10°C to 50°C Operating Humidity Range: 10% to 93% Relative Humidity, Non condensing Latching Alarm: Reset by momentary power interruption Electrical Ratings System Voltage (nominal): 3 VDC Alarm Current: 20 mA @ 24VDC
$5.00The conventional manual call point designed for conventional fire alarm system for reporting fire or emergency condition by its button latches. The call point has one 300 ohm resistor is used on the PCB board between Zone+ and Zone- or one relay contact (NO, COM, NC ) output when the button is pressed. INSTALLATION This manual should be left with the owner/user of this equipment. The call points should be installed in a position where they will not be subjected to mechanical stresses , and where the temperature is within the operating temperature range. Areas where there are , or are likely to be, aggressive substances should be avoided. Complete conventional fire alarm system manuals at manual call point SPECIFICATIONS Operating Voltage Range: 9~32VDC Volts Nominal Operating Resistance: 300Ω Relay Contact Ratings: 2A/30VDC Operating Humidity Range: 95% RH, Non-condensing Operating Temperature Range: -10°C to 50°C (14°F to 122°F) Dimensions: W89mm ,H93mm, D26mm Base Dimensions: W87mm ,H87mm, D31.5mm Weight: Net Weight 125g (with base) Colour/Case Material: Red/ ABS
$6.50The bell remains the most commonly used alarm for fire evacuation system, for wall applications, indoors. They are designed to be used in 24 volt DC systems. Specifications Voltage ranges: 20vdc to 28vdc (Nonpolarity) Power and current consumption: 1W, 38ma@24vdc(maximum) Number of standard: EN54-3 Sound level:80dB(A)@1M (minimum) Service Use: Fire alarm, general signaling, burglar alarm Environment type: Type A (indoor) Input terminal Wire Gauge: 0.28 mm2 to 1.5 mm2 Operating Temp.: -10℃ to +55℃ Operating Humidity Range: 10% to 93% Relative Humidity ( Non-condensing) Material of cover: Aluminum Dimension: 150mm×50mm(D*H) (Without bracket) Weight: Net Weight 342g, Gross Weight 395g Download fire alarm system instruction and manual at fire alarms Wiring The system designer must make sure that the total current drawn by the devices on the loop does not exceed the current capability of the panel supply, and that the last device on the circuit is operated within its rated voltage. When calculating the voltage available to the last device, it is necessary to consider the voltage drop due to the resistance of the wire. The thicker the wire, the smaller the voltage drops. Wire resistance tables can be obtained from electrical handbooks.
$9.00smoke heat detector The detector is a combined smoke and heat detector with photoelectronic sensor and heat thermistor together. This detector is designed to provide open area protection and to be used with most conventional fire alarm control panel. Two LEDs on each detector provide local 360° visible alarm indication. They flash every 3~5 seconds indicating that power is applied and the detector is working properly. The LEDs latch on in alarm. LEDs will be off when a trouble condition exists indicating that the detector sensitivity is outside the listed limit. The detector can be reset only by a momentary power interruption. Features and Benefits Compatible with all the conventional fire alarm control panel Unpolarized wire input Wide range of operating voltages Unique optical sensing chamber and High precision electronic thermistor Built in microprocessor intelligent software Two LEDs blink standby, provide 360° visibility Insect-resistant screening Twist-on mounting base with tamper lock Drift compensation and smoothing algorithms Remote Indicator LED can be connected. Complete fire alarm system category can be downloaded at fire security system Technical Specifications Diameter: 103mm Height (including mounting base): 55 mm Weight: 155 g Operating Temperature Range: -10°C to 50°C Operating Humidity Range: 10% to 93% Relative Humidity, Noncondensing Latching Alarm: Reset by momentary power interruption System Voltage (nominal): 24 VDC (9V~ 28VDC) Standby Current: 60 μA @ 24VDC Alarm Current: 30 mA @ 24VDC Fixed Temperature Rating: 57°C (135°F) Rate of Rise Detection: Responds to greater than 15°F/min
$9.00The conventional manual call point designed for conventional fire alarm system for reporting fire or emergency condition by its PUSH IN/PULL DOWN handle latches. One 470 ohm resistor is used on the PCB board between Zone+ and Zone- when the switch inside is closed. So the conventional manual call point is only used with conventional fire alarm control panel, it is forbidden to be used to other system. Conventional Manual Call Point, Operates by Advanced MCU Expert Algorithm Software. Fire alarm system category and installation instruction, datasheet, manual can be downloaded at fire alarm category Technical Specifications Ordering Information Individual(1 units) Dimensions (w x d x h millimetres) Weight 140x105x45 220g Dimension: 140mmX105mm Height: 45 mm Weight: 220 g Operating Temperature Range: -10°C to 50°C Operating Humidity Range: 10% to 93% Relative Humidity, Non condensing Latching Alarm: Reset by momentary power interruption Top Side Figure 1. Dimension of manual call point: Electrical Ratings System Voltage (nominal): 24 VDC (9V~ 28VDC) Standby Current: 60 μA @ 24VDC Alarm Current: 10~30 mA @ 24VDC call-point based upon our industry standard series housing, and features easy to install, push-fit wiring terminals. The unit can support either a 'Frangible Glass' element or a 'Non Frangible Plastic' element. Push in and Pull Down Call Point Can be reset by key Red colour Fire proof materials 470 Ohm Resistance Modern style Call Point
$9.50The device is photo-electronic detector uses a state of-the-art optical sensing chamber. This detector is designed to provide open area protection and to be used with most conventional fire alarm control panel. Two LEDs on each detector provide local 360° visible alarm indication. They flash every 3~5 seconds indicating that power is applied and the detector is working properly. The LEDs latch on in alarm. LEDs will be off when a trouble condition exists indicating that the detector sensitivity is outside the listed limit. The detector can be reset only by a momentary power interruption. Find datasheet and installation manual of fire alarms at conventional smoke detector Features and Benefits: Compatible with all the conventional fire alarm control panel Un-polarized wire input Wide range of operating voltages Unique optical sensing chamber Built in microprocessor intelligent software Two LEDs blink standby, provide 360° visibility Insect-resistant screening Twist-on mounting base with tamper lock Drift compensation and smoothing algorithms Remote Indicator LED can be connected. Technical Specifications Diameter: 103mm Height (including mounting base): 55 mm Weight: 155 g Operating Temperature Range: -10°C to 50°C Operating Humidity Range: 10% to 93% Relative Humidity, Noncondensing Latching Alarm: Reset by momentary power interruption System Voltage (nominal): 24 VDC (9V~ 28VDC) Standby Current: 60 μA @ 24VDC Alarm Current: 30 mA @ 24VDC
$9.50Fire fighting gas system The Manual release is connected with Fire fighting panel. There are three buttons on the station, one is START button, and another one is STOP button. When the START button is pressed, you can press RESTORE button to restore the start button. Fire alarm and automatic fire fighting system component with instruction. Learn to install fire alarm system easy with video guidegas release fire fighting
$10.00Conventional Probe Heat Detector Fire Detector Heat sensor Temperature alarm The device is intelligent sensors that utilize a state-of the-art thermistor sensing circuit for fast response. These sensors are designed to provide open area protection with 50 foot spacing capability. The device is a rate-of-rise temperature sensor with 135°F fixed temperature alarm. The device is a rate-of-rise with fixed temperature alarm thermal detector utilizing a state-of-the-art dual thermistor sensing circuit. These detectors are designed to provide open area protection with 50-foot spacing capability, and are to be used with compatible control panels only. Two LEDs on each detector light to provide 360°visibility of the detector indication. Features and Benefits Compatible with all the conventional fire alarm control panel Unpolarized wire input Wide range of operating voltages High precision electronic thermistor Built in microprocessor intelligent software Two LEDs blink standby, provide 360° visibility Insect-resistant screening Twist-on mounting base with tamper lock Remote Indicator LED can be connected. Download fire alarm system installation manual at heat detector Technical Specifications Diameter: 103mm Height (including mounting base): 55 mm Weight: 155 g Operating Temperature Range: -10°C to 50°C Operating Humidity Range: 10% to 93% Relative Humidity, Noncondensing Latching Alarm: Reset by momentary power interruption System Voltage (nominal): 24 VDC (9V~ 28VDC) Standby Current: 40 μA @ 24VDC Alarm Current: 30 mA @ 24VDC Fixed Temperature Rating: 57°C (135°F) Rate of Rise Detection: Responds to greater than 15°F/min
$10.00Measuring Range of 0~100% LEL combustible gas leakage alarm. This detector can be wall-mounted and cabled easily (AC 220V-plug, DC 12V solenoid valve-plug). It is stable and don't need commission, with wide range ofenvironmental adoption. JT-TC521 independent detector is widely used in houses, hotels, apartments or other places that combustible gas may exist. This detector can monitor natural gas, liquefied petroleum gas and artificial gas. Features ● Equip with high-quality gas sensor, reliable and corresponding. ● The intelligent algorithm of the microprocessors can compensate for the drift of gas sensor. ● The precision temperature sensor is a supplement of the monitoring of the environment temperature, which completely eliminates false alarms. ● LEDs indicate the detector status of normal, alarm and fault. ● The shell of the detector use fire-resistant ABS engineering plastic, clean and generous. Technical Specifications 1) Operating power: AC 220V 2) Standby current: 6 mA 3) Alarming current: 7 mA 4) Ambient temperature: -10℃~+50℃ 5) Operating humidity: ≤95%RH 6) Sound level: >75dB 7) Pressure: 86kPa-106kPa 8) First stabilization period: 3 min 9) Expiration date of sensor: >5 years(in clean air) 10) Alarm threshold: methane: 8% LEL 11) Detecting gas: available for natural gas, artificial gas, liquefied petroleum gas and many other kinds of combustible gas. 12) Output contact: active contact, available for one-way pulse electromagnetic valve of DC 12V; the drive capability of electromagnetic valve: 1000 μF capacity discharge. 13) Wiring: ①White plug: Connecting DC 12V solenoid valve ②White terminal: Connecting AC 220V 14) Dimension: 120mm×86mm×48mm
$16.50Detect natural gas, manufactured gas, liquefied petroleum gas and other combustible gas. JT-TC516 Combustible Gas Detector With Measuring Range of 0~100% LEL. It adopts advanced normal temperature semiconductor gas sensor, microprocessor combined with precision temperature sensor. It can intelligently compensate the drift of gas sensor, and the environmental adaptation range is wide. ▪ Electronically coding ▪ Ceiling-mounted ▪ Electronically addressed ▪ Widely used in homes, hotels, apartments and other places where combustible gas exists ▪ Detect natural gas, manufactured gas, liquefied petroleum gas and other combustible gas ▪ Active contact, applying to DC12V Single-phase dc pulse solenoid valve; the drive capability of a solenoid valve: 1000µF capacity discharge Technical Specifications Operating voltage: DC24V Standby current: 21mA Alarm current: 28mA Operating Environment: Temperature: -10°C~+50°C,Relative Humidity: ≤95% Sound level: >75dB Pressure: 86kPa-106kPa Dimension: 100mm×51mm (with base) First stabilization period: 3 min Expiration date of sensor: >5 year(s in clean air) Alarming threshold: methane: 8% LEL Detecting gas: available to detect natural gas and many other kinds of combustible gas containing methane. Encoding mode: addressable Wiring: ①Terminal No. 1, 4: DC 24V input power line, non-polarized. ②Terminal No. 2, 3: non-polarized input signal cable, connecting the loop of control panel JT-TC516 Addressable Combustible Gas Detector should work with gas monitor panel JB-KR-TC5306
$18.0024v conventional gas extinguisher and fire alarm system compatible gas release lamp 1. Comptaible with all the fire fighting panel 2. DC24V powered 3.LED light long life 4.Easy Installation Learn to install fire alarm system. Step by step instruction of fire alarm and fire automatic fighting system fire alarm fighting
$18.00Conventional Maintenance Switch For Gas Extinguisher System This MAINTENANCE panel is a key switch, which disconnects actuation circuits in the system to prevent accidental discharge during maintenance operations. Two “LEDS” indicate “SYSTEM ARMED” and “SYSTEM INACTIVE”. When the key is inserted and turned towards “SYSTEM INACTIVE”, the red LED illuminates and the green LED indicating “SYSTEM ARMED” turns off. The key can only be removed in the “SYSTEM ARMED” position. This panel is also available with the key removable in both the “ARMED” and the “INACTIVE” positions. The information is silk-screened on a two-gang stainless plate. Switch rated at 5A 250VAC, the DC rating is 5A up to 30VDC. LEDS rated at 10mA each for a total current draw of 20mA. Video guidance to instruct how to install gas fire extinguishing fire alarm and fire automatic fighting system fire fighting
$19.00JT-TC518 Addressable Combustible Gas Detector of Measurement Range 0-100%LEL It adopts advanced semiconductor gas sensors using at room temperature and microprocessors in conjunction with precision temperature sensor, which can compensate for the drift of intelligent gas sensor. This detector can be wall-mounted and cabled easily. It is stable and don't need commission, with wide range of environmental adoption. JT-TC518 addressable detector is widely used in houses, hotels, apartments or other places that combustible gas may exist. This detector can monitor natural gas and other combustible gas containing methane. Features ● Equip with high-quality gas sensor, reliable and corresponding. ● The intelligent algorithm of the microprocessors can compensate for the drift of gas sensor. ● The precision temperature sensor is a supplement of the monitoring of the environment temperature, which completely eliminates false alarms. ● LEDs indicate the detector status of normal, alarm and fault. ● The shell of the detector use fire-resistant ABS engineering plastic, clean and generous. Technical Specifications 1) Operating power: DC 24V 2) Standby current: 21 mA 3) Alarming current: 28 mA 4) Ambient temperature: −10℃〜+50℃ 5) Operating humidity: ≤95%RH 6) Sound level: >75dB 7) Pressure: 86kPa-106kPa 8) First stabilization period: 3 min 9) Expiration time of sensor: >5 years(in clean air) 10) Alarming threshold: methane: 8% LEL 11) Detecting gas: available to detect natural gas and many other kinds of combustible gas containing methane. 12) Output contact: active contact, available for one-way pulse solenoid valve of DC 12V; the drive capability of solenoid valve: 1000 μF capacity discharge 13) Encoding mode: addressable 14) Wiring: ①White plug: Connecting DC 12V solenoid valve ②Black line: Connecting DC 24V ③White line: Connecting the loop of control panel 15) Dimension: 120mmX86mmX48mm
$20.00Outdoor sound flash light alarm. Suitable for patrol, fire, medical and so on. The alarm sound is strong, can obtain the visual and auditory shock effect with the low voltage and low power input. Product technical parameters 1. Working voltage: DC12-30V 2. Working current: ≤40mA 3. Working environment: -20℃ ~ +60℃ 4. Relative humidity: 0%~95%RH 5. Sound intensity: greater than or equal to 105dB (at a distance of one meter) 6. Product weight: 360g net weight 7. Flash intensity: greater than or equal to 1.2WS More details and complete fire alarm system category can be found at fire alarm
$24.00Gas release lamp Deflation indicator FQ119 technical parameter 1. working voltage: DC24 + 15% (no polarity) 2. rated current: less than 60mA 3. ambient temperature: -10 C +55 C 4. relative humidity: less than 95%. 5. flash strength: more than 1.2WS 6. the number of light: = 120 times / min 7. life is more than 30000 times: strobe flash 8. product size: 300*120*26mm Contact us if you have any inquiry of fire alarm and fire automatic fighting.
$25.00Maintain fire alarm system regularly easy with maintence panel for switch. This MAINTENANCE panel is a key switch, which disconnects actuation circuits in the system to prevent accidental discharge during maintenance operations. Two “LEDS” indicate “SYSTEM ARMED” and “SYSTEM INACTIVE”. When the key is inserted and turned towards “SYSTEM INACTIVE”, the red LED illuminates and the green LED indicating “SYSTEM ARMED” turns off. The key can only be removed in the “SYSTEM ARMED” position. This panel is also available with the key removable in both the “ARMED” and the “INACTIVE” positions. The information is silk-screened on a two-gang stainless plate. Switch rated at 5A 250VAC, the DC rating is 5A up to 30VDC. LEDs rated at 10mA each for a total current draw of 20mA.
$30.00Fire floor display and repeat panels have the following key features: 16 conventional repeater display zones. Fire alarm output relay and 1 fault output relay . Fire alarm output with 24VDC. RS485 can be able to connect the other panel. You can download the complete fire alarm system category and installation instruction manual fire alarm installation Specifications Power supply: 16VDC to 30VDC Current of power: Standby current: ≤15mA, Alarm current: ≤75mA Relay contact capacity: 2A@24VDC Buzzer level: 80dB@1m. Protection level: IP55 Communication mode:RS485 (Wires: RVSP type,1.0MM2 to 2.0MM2) Dimension of enclosure: 200mm(W)*91mm(H)*45mm(D) Material of enclosure:ABS, White Weight: 350g. Hole of enter wires: 1/2 inch(12mm) Repeater status indication and button operation FIRE ALARM Status: When a fire alarm occurs, the corresponding zone red LED flashing and the internal buzzer sounds. When “Silence” button pushed, the alarm zone LED lights steady and the buzzer silenced. When another new fire alarm occurs, the new zone red LED flash and the buzzer sound again. In the fire alarm status, the fire alarm “FIRE OUT” relay active and output “NO, NC, C” relay contacts and 24vdc power output. FAULT Status: When a fault event occurs, the corresponding zone’s yellow LED flashing and the internal buzzer sounds. When “Silence” button pushed, the fault zone LED lights steady and the buzzer silenced. When another new fault event occurs, the new zone yellow LED flash and the buzzer sound again. In the fault alarm status, the fault alarm “FAULT OUT” relay active and output “NO, NC, C” relay contacts. Normal status: When fire alarm panel’s fire or fault event restored, the fire alarm panel would send commands to let the repeater to the Normal Status. RUN LED: The “RUN” LED would keep light steady when the power supply in normal status. COMM. LED: The “COMM.” LED would flash once about three to five seconds in normal communication status. SILENCE LED: In the fire or fault alarm status, press the “Silence” button the “SILENCE” LED would turn on . TEST LAMP: In normal status, press “TEST” button would have a lamp test. SILENCE SOUND: In fire or fault status, press “SILENCE” button would silence the alarm sound. RESET: In the “SILENCE” status,press “RESET” button once the repeater would return to the Normal Status.
$67.00Small business fire security alarm system. CP-1002 Mini size designed conventional fire alarm 2 zone panel is used for family hotel fire security, restaurant fire security, store or shop fire security alarm. Automatic fire alarm system is a device that automatically detects, displays and sends out fire alarm when fire occurs to the protected object. It is widely used in modern factories, material warehouses, high-rise buildings, computing centers and other buildings, to ensure the safety of people's lives and property plays a huge role. Automatic fire alarm system is composed of trigger device, fire alarm device, fire alarm device, power supply and linkage device with other auxiliary control function. Conventional 2-zone multi-wire fire alarm controller, equipped with any 2-wire smoke, temperature, alarm button and alarm bell, sound and light. At the same time can be equipped with security alarm equipment. More fire alarm systems with free technical support at conventional fire alarm Description: 1. The Mini fire alarm control master panel and slave panel each has 2 zones and each zone can equip Max.30 detectors and call points. 2. It should be installed, commissioned and maintained by suitably qualified service personnel with reference to IEE regulations and any statutory requirements. 3. The 2 zones alarm panel has 1 alarm sound output zones (bell zones), which can equip max.16 sounders for total max. 1A/24V power supplied. 4. The panel (master or slaver) has 24V auxiliary power output supply 2A/24V with fire 1, fire 2 relay output and fault relay output. 5. It is external DC24V power supplied with backup battery. 6. It supports detector head removal and easy for repair or maintenance. 7. It has Test/reset, silence alarm and Evacuate button for easy panel operation. 8. It has indicators of zone1 alarm /fault, zone2 alarm /fault, Sound alarm, and sound fault LED. That clearly showed detectors and sound circuit staturs. 9. There is one master fire alarm control panel and it can work with Max.31 same slaver panel. 10. The master fire control panel will communicate slaver panel one by one and fault will be showed if no response is received. 11. Alarm and fault events of panel No. and zone No. will be showed one by one on Master fire control panel. Specification: 1. System Power Supply: It is external 22-26VDC power supplied. (With upgrade version with internal power supply available) 2. Standby current: <50mA 3. Alarm current(not include the others): <150mA 4. Detector Voltage (VDC): 24V 5. Number of sensor zones: 2 zones 6. Max. number of detectors per zone: 30 7. Alarm Voltage: 24V 8. Number of alarm zone: 1 9. Max. Alarm current per zone: 300mA 10. Max. number of sounders per zone: 16 11. Max. sounder supply current in fire: 1A/24V 12. Fire fault relay contacts loads: 2A/24V 13. Panel weight without battery: 520g 14: Diameter: 108mm*143mm*40mm upc code: 782123753055 ean code: 0782123753055
$98.00