TC5402W wireless heat detector is an intelligent household fire detector with high- precision thermostor as the sensor, which can be used together with the wireless fire alarm control panel. The detector uses advanced wireless transceiver technology and high-integration micro-processing chip to process data. Technical Data All data is supplied subject to change without notice. Specifications are typical at 24V, 25℃ and 50% RH unless otherwise stated. Battery CR17450 3V Operating current monitoring current≤3uA , alarm current≤18mA Coding method automatically assigned when networking Radio frequency transmit power<20dBm Frequency band 470MHz Communication distance ≤500m Communication method 470MHz FSK coded bidirectional Operating environment temperature 10℃~+55℃ relative humidity ≤95% Dimension 100mm*54mm(with base) Weight 110g Using advanced wireless transceiver technology, signal transmission can be completed without wiring, and the project is simple and convenient. It adopts 470MHz communication and FSK coding technology, which has strong anti- interference ability and long transmission distance Low-voltage battery detection, reminding the user to replace the battery when it is insufficient to maintain the normal operation of the detector.
$22.50Addressable fire alarm system LPCB EAC certificate professional fire security equipment. Heat Detector LPCB CE EN54 works with TC-5109 Advanced single-chip microcomputer technology Non-polarized two-wire Indoor garage, kitchen, boiler room, generator room, drying room and other places Approvals:LPCB(EN54-5) CE Technical Specifications Operating voltage Loop 24V(18.5V~26V) Operating current Standby current: ≤0.3mA;Alarm current: ≤0.8mA Operating Environment Temperature: -10°C~+50°C;Relative Humidity: ≤95%, non-condensing Indicator Red,Flashes when polling,Illuminates in alarm Ingress protection rating IP33 Material and color of enclosure ABS; Milky white Coding method Electronically coding Code range 1~255 Weight About 110g Mounting hole distance 60mm Dimension 100mm×50mm (with base) Product installation manual and video at heat detector
$16.80Fire alarm siren works with TC series addressable fire alarm system TC-5109 LPCB alarm panel. LPCB certified addressablel horn strobe flash and sounder Installed in public places A kind of audio and visual alarm device used to warn people in field when fire occurs Four wires:non-polarized signal two-wire, and non-polarized DC24V power two-wire Built-in microprocessor Self-diagnostic function Electronically coding Approvals:LPCB(EN54-3) CE Technical Specifications Operating voltage Loop: 24V (16V~28V);Power: DC24V (DC19V~DC28V) Standby current Loop: ≤0.2mA;Power: ≤0.5mA Active current Loop: ≤1.5mA;Power: ≤50mA Operating Environment Indoor (Non-residential);Temperature: -10°C~+50°C; Relative Humidity: ≤95%(40±2°C) Sound level 80dB~115dB (A weighted) Pitch shift periodic 3.5S~4.5S Basic flashing frequency 1Hz~2Hz Weight 200g Dimension (L×W×H) 115mm×55.3mm×140mm Product installation manual and video can be found at fire horn
$18.50Measuring Range of 0~100% LEL combustible gas leakage alarm. This detector can be wall-mounted and cabled easily (AC 220V-plug, DC 12V solenoid valve-plug). It is stable and don't need commission, with wide range ofenvironmental adoption. JT-TC521 independent detector is widely used in houses, hotels, apartments or other places that combustible gas may exist. This detector can monitor natural gas, liquefied petroleum gas and artificial gas. Features ● Equip with high-quality gas sensor, reliable and corresponding. ● The intelligent algorithm of the microprocessors can compensate for the drift of gas sensor. ● The precision temperature sensor is a supplement of the monitoring of the environment temperature, which completely eliminates false alarms. ● LEDs indicate the detector status of normal, alarm and fault. ● The shell of the detector use fire-resistant ABS engineering plastic, clean and generous. Technical Specifications 1) Operating power: AC 220V 2) Standby current: 6 mA 3) Alarming current: 7 mA 4) Ambient temperature: -10℃~+50℃ 5) Operating humidity: ≤95%RH 6) Sound level: >75dB 7) Pressure: 86kPa-106kPa 8) First stabilization period: 3 min 9) Expiration date of sensor: >5 years(in clean air) 10) Alarm threshold: methane: 8% LEL 11) Detecting gas: available for natural gas, artificial gas, liquefied petroleum gas and many other kinds of combustible gas. 12) Output contact: active contact, available for one-way pulse electromagnetic valve of DC 12V; the drive capability of electromagnetic valve: 1000 μF capacity discharge. 13) Wiring: ①White plug: Connecting DC 12V solenoid valve ②White terminal: Connecting AC 220V 14) Dimension: 120mm×86mm×48mm
$16.50Electrical fire monitoring system residual current detector. Built-in processor can receive the signal from transformer and handle those signal into two forms as normality and alarming, both of which will be transmitted to the electrical fire monitoring equipment. The microprocessor will transmit the mode status of normality or alarming to monitoring devices. How to use electric fire monitor equipment and how to install? Technical Features 1. Operating Voltage: Pulse voltage of circuit loop: Loop 24V Available range: 16V~30V 2. Operating current: Standby current≤0.4mA Alarming current≤0.7mA 3. Rated alarming current: 200mA~1000mA, step-size 1mA 4. Encoding mode: electrical addressable mode. It takes one site on the loop. And an addressable code could be any in the range of 1~255. 5. Cabling: connecting with the monitoring devices through signal nonpolar two-line loop. 6. Aperture of wires: 93mm 7. Rated operating current of main loop: less than 630A. 8. Rated frequency of wires: 50Hz/60Hz 9. Ambient environment: Temperature: -10℃~+55℃ Relative humidity≤95%, non-condensing 10. Dimension: 188mm × 145mm × 45mm 11. Enclosure material: ABS plastic 12. Ingress Protection Rating: IP30 13. Weight: about 1.3kg
$55.00TC5163 Addressable Heat & Smoke Multi Detector:
1. There are 2 conductor pieces with terminals on the base.
Loop of the detector should be connected with two terminals (polarity-insensitive).
After the base is fixed firmly, rotate the bottom of detector and base clockwise, and then the detector will be fitted to the base
2. 1.0mm2 or above RVS twisted pair, laid out through metal conduit or flame-resistant conduit.
TC5163 Smoke and Heat Combined Detector Features:
1. Supervising external circuits function for input and output
2. single chip processes data in real time
3. drift compensation and dust accumulation and report pollution self-diagnosis function
4. non-polarized two wire bus signal fire alarm
TC5163 Smoke and Heat Combined Detector Specification:
Operating Volate: loop 24V(16~28V)
Operating Current: Monitoring current: ≤ 0.3mA ;Alarm current: ≤ 0.9mA
Weight: About 110g
Protected area: 20~30m2
Operating environment: Temperature: -10℃~+55℃; relative humidity: ≤95%, non-condensing
Dimension: 100mm×51mm
Mounting hole distance: 60mm
Ingress protection rating: IP23
Material and color: ABS;Milky white
Maximum transmission range: 1500m

TCSG5416W wireless sounder strobe is suitable for installation in public places, factories and other environments, and is used together with JB-TB- TC5126W wireless fire alarm control panel. When the control panel receives the fire alarm instructions from other fire alarm devices, the control panel starts the alarm through wireless signals, and the alarm sends out sound and light signals to achieve the purpose of audible and visual alarm. Technical Data All data is supplied subject to change without notice. Specifications are typical at 24V, 25℃ and 50% RH unless otherwise stated. Battery CR17450-2-080-02 Rated Operating Voltage DC3V Operating current monitoring current≤45uA , alarm current≤240mA Sound level 75dB~115dB Coding method automatically assigned when networking Radio frequency transmit power<20dBm Communication method 470MHz FSK coded bidirectional Communication distance ≤500m Operating environment temperature 10℃~+55℃ relative humidity ≤95% Dimension 101mm*137mm*43mm Weight 170g The 470MHz wireless communication technology is adopted, and no embedded wiring is needed, so the engineering installation is convenient and quick; With battery low voltage detection function, it can reflect the battery power situation in time; The microprocessor is used to realize signal processing, and the digital signal is used to communicate with the control panel, which works stabely and reliably, and has a good ability to suppress electromagnetic interference.
$38.00TCMK5265 Addressable I/O Module non-polarized two bus,ultra-low power consumption,no need to add DC24V power supply passive outputvv input and output have isolating loop to effectively filter out external interference 1.Fix the base with two tapping screws,and then connect loop to terminals(polarity-insensitive).After thebase is fixed firmly,rotate the bottom of detector and base clockwise,and then the detector will be fitted tothe base. 2.Wiring instructions:RVS twisted pair with cross-sectional area≥1.0mm2 should be selected for the secondbus of the detector,which should be laid through metal pipe or flame retardant pipe.The length of theconnecting wire should be limited to the single bus resistance≤20Q,otherwise the wire diameter should beincreased. Rated operating voltage Loop:24V(14V~28V); Operating current Monitoring current: ≤ 0.2mA start current: ≤ 0.5mA Operating Environment Temperature:-10℃~+55℃; Relative Humidity:≤95% non-condensing Input supervisory external loop Open circuit occurs when normally open terminal supervising externalloop (short circuit is an action signal), the module will send a fault signalto the control panel. Material and color ABS;Porcelain white Output supervisory external loop Short circuit or open circuit on the output loop occurs, the module will send a fault signal to the contaol panel Weight 147g Mounting hole distance 60mm Dimension(L×W×H) 86mm×38mm×86mm(with base)
$20.00LPCB CERTIFIED TCMK5261 Addressable Single Input Module is used to receive normally open or normally closed swtich signals input by the fire linkage equipment, and transmit linkage information back to the Fire Alarm Control Panel TC5109 (linkage).
Input terminal can be set as normally open and normally closed on-site, which should be connected with passive contact.
The microprocessor monitors the operation situation and transmits the status of the module to the control panel in 3 forms: normal, action and fault.
The circuit part and wiring base are plugged, which is reliable in contact and convenient for construction.
Designed to connect with active devices in field such as water flow indicator, pressure switch, position switch, signal valve and devices able to transmit back switch signals
The built-in microprocessor processes messages intelligently
Plug-in structure
Non-polarized two-wire
Operating voltage: Loop 24V (16V~28V)
Operating current: Standby current:≤0.2mA; Action current:≤0.8mA
Operating Environment
Temperature:-10℃~+55℃; Relative Humidity:≤95% non-condensing
Code range: 1~255
Material and color of enclosure: ABS; Porcelain white
Weight: About 110g(with base)
Mounting hole distance: 60mm
Mounting hole distance: 60mm
Dimension(L×W×H): 86mm×38mm×86mm(with base)
Residual Current Electrical Fire Monitoring Detector TC-DH01B-J225 Through-line aperture: 225 × 56mm main circuit rated operating current: less than 630A Dimensions: 296mm × 166mm × 45mm Standard: GB14287.2-2014 "Electric Fire Monitoring Systems - Part 2: Residual Current Electric Fire Detectors” The Detector builds up an electrical fire monitoring system with our productions of JB-DH-TC5600 Electrical Fire Monitoring Equipment, TC-DH12A Combined Electrical Fire Monitoring Detector and TC-DH230 Combined Electrical Fire Monitoring Detector. The Detector can realize the function of leakage test, temperature test and output controlling by connecting with JB-DH-TC5600 Electrical Fire Monitoring Equipment through two-line loops. It can also connect with many other kinds of residual current transformers to realize stable and reliable operating. Electrical fire monitoring system can effectively prevent electrical fires and reduce losses. Technical Specifications: 1. Operating Voltage: Pulse voltage of circuit loop: Loop 24V Available range: 16V~30V 2. Operating current: Standby current≤0.4mA Alarming current≤0.7mA 3. Rated alarming current: 200mA~1000mA, step-size 1mA 4. Encoding mode: electrical addressable mode. It takes one site on the loop. And an addressable code could be any in the range of 1~255. 5. Cabling: connecting with the monitoring devices through signal nonpolar two-line loop. 6. Aperture of wires: 225mm×56mm 7. Rated operating current of main loop: less than 630A. 8. Rated frequency of wires: 50Hz/60Hz 9. Ambient environment: Temperature: -10℃~+55℃ Relative humidity≤95%, non-condensing 10. Dimension: 296mm×166mm×45mm 11. Enclosure material: ABS plastic 12. Ingress Protection Rating: IP30 13. Weight: about 3kg
$60.00TCMK5269 Dual Input Module is used to receive normally open or normally closed switch signal input by fire linkage equipment, and transmit linkage information back to Fire Alarm controller (linkage type TC5109). It is mainly used to connect various active equipment such as water flow indicator, pressure switch, position switch, signal valve and external linkage equipment which can send back switch signal, etc. After the operation of these devices, the output action signals can be sent by the module to the fire alarm controller through the signal bus to generate an alarm, and the fire alarm controller can be used to linkage the actions of other related devices.
Characteristics
1. The module has two input terminals, respectively input 1 and input 2, respectively corresponding to two addresses;
2. The input line has the function of checking the line, and when the line breaks down, the fault information will be reported;
3. The address code is electronic code, which can be written in advance by the electronic encoder, so the engineering debugging is simple and reliable.
4. Using microprocessor to realize signal processing, using digital signal to communicate with the controller, the work is stable and reliable, and has a good ability to restrain electromagnetic interference
Compatible LPCB Addressable Fire Alarm Systems.

Addressable fire alarm system TC-5109 compatible Single I/O Module LPCB intelligent Module Designed to connect with linkage devices of fire alarm controlpanel, such as exhaust valve, air valve, fire damper etc., and can receive feedback signal from device Non-polarized two-wire Active and passive output The input terminal can be in field set to normally open detecting wire or self-feedback mode, which can be connected with passive contact Approvals:LPCB(EN54-18) CE Technical Specifications Operating voltage Loop:24V (18.5V~26V);Power: DC24V (DC19V~DC28V) Standby current Loop: ≤0.2mA;Power: ≤2mA Starting current Loop: ≤2mA;Power: ≤22mA Operating Environment Temperature: -10°C~+55°C;Relative Humidity: ≤95%, non-condensing Output capacity Passive:Capacity: DC30V/3A;Contact resistance in normal condition: 100kΩ;Closed when activated;Suitable for DC or AC12V~48V;Active output: DC24V/1.5A Indicator Red,Input indicator,Flashes when polling,Illuminates in action,Output indicator,Illuminates in action Coding method Electronically coding Code range 1~255 Material and color of enclosure ABS; Porcelain white Weight About 147g (with base) Mounting hole distance 60mm Dimension (L×W×H) 86mm×38mm×86mm (with base) Product installation manual and video at fire alarm module
$17.90TCXH5415W wireless fire hydrant button is suitable for installation in public places. when manually confirming to start the fire pump, press the start button on the fire hydrant button, and the red light of the fire hydrant button is always on, which can send a start signal to the control panel through wireless communication technology and start the fire pump at the same time; After the fire pump has been started, the fire hydrant button answer light is always on, the fire hydrant button sends an answer signal to the control panel through wireless communication technology, and the fire hydrant button enters the state of waiting for the control panel to reset. The control panel can display the coded information of hydrant button and make sound. Technical Data All data is supplied subject to change without notice. Specifications are typical at 24V, 25℃ and 50% RH unless otherwise stated. Battery CR17450 Rated Operating Voltage 3V Operating current monitoring current≤15uA , alarm current≤10mA Coding method automatically assigned when networking Radio frequency transmit power<20dBm Communication distance ≤500m Communication method 470MHz FSK coded bidirectional Operating environment temperature 10℃~+55℃ relative humidity ≤95% Dimension 96mm*95mm*50mm Weight 190g The 470MHz wireless communication technology is adopted, and no embedded wiring is needed, so the engineering installation is convenient and quick; With battery low voltage detection function, it can reflect the battery power situation in time; The microprocessor is used to realize signal processing, and the digital signal is used to communicate with the control panel, which works stable and reliably, and has a good ability to suppress electromagnetic interference.
$26.50Residual Current Transformer TC-DH01B-J325 Through-line aperture: 325 × 60mm main circuit rated operating current: less than 1000A Dimensions: 445mm × 220mm × 60mm Connected to the monitoring device JB-DH-TC5600 with a non-polar two buses, while achieving communication and power supply functions The address code is electronically encoded and can be written in advance by the electronic encoder. The engineering debugging is simple and reliable The microprocessor monitors the operation and transmits the status of the module to the monitoring device in both normal and alarm modes Wire system: non-polar connection to the signal bus of the monitoring device Residual current detector Specification: 1. Operating Voltage: Pulse voltage of circuit loop: Loop 24V Available range: 16V~30V 2. Operating current: Standby current≤0.4mA Alarming current≤0.7mA 3. Rated alarming current: 200mA~1000mA, step-size 1mA 4. Encoding mode: electrical addressable mode. It takes one site on the loop. And an addressable code could be any in the range of 1~255. 5. Cabling: connecting with the monitoring devices through signal nonpolar two-line loop. 6. Aperture of wires: 325mm×60mm 7. Rated operating current of main loop: less than 1000A. 8. Rated frequency of wires: 50Hz/60Hz 9. Ambient environment: Temperature: -10℃~+55℃ Relative humidity≤95%, non-condensing 10. Dimension: 445mm×220mm×60mm 11. Enclosure material: ABS plastic 12. Ingress Protection Rating: IP30 13. Weight: about 8kg
$99.00TCSB5214H TC fire alarm system series LPCB approval addressable 2-wire bus type Voltage: Loop DC24V(16V-28V) Digital Manual Call Point (With Jack) (MCP) is installed in public places. The MCP contains a phone jack. And when there is a fire, pressing the frangible element on this MCP can send fire signal to Fire Alarm control panel. After receiving the signal, the control panel will show address information of the MCP and generate alarm sound. Insert the Fire Telephone handle into the phone jack, and then communicate the fire telephone panel. Features 1.Plug-in structure. Simple and convenient installation. Alarm by pressing, reset by a special key. 2.Pressing the frangible element and it can provide independent output contact through the MCP. And it can directly control other peripheral devices. 3.Microprocessor processes signal and digital signal communicates the Fire Alarm Control Panel. Stable and reliable work, good ability to inhibit electromagnetic interference. 4.Electronically addressed. The address can be modified in field. Easy and reliable for commissioning. Technical Specifications 1.Operating voltage Signal bus voltage: loop 24V 2.Operating current Standby current: ≤ 0.2mA Alarm current: ≤ 0.8mA 3.Type of initiating part: Reusable 4.0Initiating mode: Pressing the frangible element manually 5.Resuming mode: Manually resumed by a special key 6.Indicator Running/fire LED: Red. Flashes every 3s when polling. Illuminates after alarming. Fire telephone: Red. Flashes every 5s. 7.Programming mode Electronically addressed (address range: one address within 1~255). 8.Wiring Non-polarized signal two-wire 9.Operating environment Class: indoor Temperature: -10°C~+55°C Relative Humidity: ≤95%, non-condensing 10.Dimension Diameter: 90mm×90mm×42 mm (with base) 11.Material and color of enclosure: ABS; red 12.Weight: about 120g(with base) 13.Mounting hole distance: 60mm 14.Standard: GB 19880-2005 Call Point with Jack
$15.901. Zone Monitoring Interface Description:
TCMK5271 is mainly used to connect external multi-wire conventional detectors to the loop signal bus. It is used to monitor the status of external multi-line equipment and transmit its status to the control panel through the bus. When any detector in the loop sends an alarm signal, the area monitoring interface receives the information and uploads it to the control panel.
2. TCMK 5271 Zone Monitoring Interface Features:
It has the function of detecting the wiring fault of external multi-line equipment;
The address code is electronically coded, which can be written in advance by the electronic encoder, and the engineering debugging is simple and reliable.
Wall-mounted, small size.
3. Specification:
Operating voltage: Rated working voltage of signal bus: bus 24V range: DC16V~DC28V
Power supply rated working voltage: DC24V range: DC20V~DC28V
Operating current:
Bus monitoring current ≤0.25mA
Bus starting current ≤ 0.8ma.
Monitoring current of power supply ≤10mA
and starting current of power supply ≤25mA
Output capacity:
each interface can have up to 30 detectors.
Indicator light:
red, fire alarm light, shining during patrol inspection, and always on. Yellow, fault light, always on.
Coding mode:
electronic coding mode, occupying one bus coding point,
and the coding range can set between 1 and 255.
Wire:
Connect with the signal bus 2-wire of the control panel and the power line
Environment:
Temperature:-10℃ ~+55℃
Relative humidity ≤95%, non-condensing.
Overall dimensions:
86mm×86mm×40mm (with bottom shell)
Material and color:
ABS, porcelain white
Weight:
about 300g
Installation hole distance:
60mm
TCTXM5000-RS MODBUS-RTU CONVERTER is a protocol repeater for fire alarm system monitoring. This product adopts serial communication technology, through accurate data acquisition technology, to monitor, collect and analyze data in an all-round way. Through advanced serial port data transmission technology, the collected data will be sent to the end user. It can monitor the equipment in the fire alarm control panel in real time: alarm, start, stop, feedback, failure, shielding, and supervision and other parameters, the information of the fire alarm control panel can be inquired according to different partitions and addresses. It is easy to install and adopts RS485 serial communication technology to support long-distance wiring. Convenient debugging, configuration parameters can be debugged through the computer serial port, simple, convenient and fast. It is easy to debug and can monitor various parameters of the fire alarm system in real time. When there is information such as fire alarm or fault, the information can be uploaded to the user monitoring system through the serial port query to realize real-time monitoring and real-time processing.
$300.00TCMK5411W wireless input module is suitable for installation in public places, factories and other environments. When there is a fire alarm, the module will send an alarm signal to the control panel through wireless communication technology after receiving the input signal specified by the manufacturer, and the red light is always on. Technical Data All data is supplied subject to change without notice. Specifications are typical at 24V, 25℃ and 50% RH unless otherwise stated. Battery CR17450 Rated Operating Voltage 3V Operating current monitoring current≤13uA , alarm current≤20mA Coding method automatically assigned when networking Radio frequency transmit power<20dBm Communication method 470MHz FSK coded bidirectional Communication distance ≤500m Operating environment temperature 10℃~+55℃ relative humidity ≤95% Dimension 101mm*137mm*43mm Weight 160g The 470MHz wireless communication technology is adopted, and no embedded wiring is needed, so the engineering installation is convenient and quick; With battery low voltage detection function, it can reflect the battery power situation in time; The microprocessor is used to realize signal processing, and the digital signal is used to communicate with the control panel, which works stable and reliably, and has a good ability to suppress electromagnetic interference.
$25.50