Addressable Fire Alarm Loop Isolator Module TCMK5210 Wiring type: Non-polar two bus Type: Isolator Action Current: 170mA/270mA Load Capcaity: Loop,24V,170mA/270mA (B, ZX2 short circuit) Mounting Hole Distance: 60mm Ingress Protection Rating: IP30 Specification: 86mm*86mm*40mm (with base) Approval: LPCB, CE, GOST
$18.00JT-TC518 Addressable Combustible Gas Detector of Measurement Range 0-100%LEL It adopts advanced semiconductor gas sensors using at room temperature and microprocessors in conjunction with precision temperature sensor, which can compensate for the drift of intelligent gas sensor. This detector can be wall-mounted and cabled easily. It is stable and don't need commission, with wide range of environmental adoption. JT-TC518 addressable detector is widely used in houses, hotels, apartments or other places that combustible gas may exist. This detector can monitor natural gas and other combustible gas containing methane. Features ● Equip with high-quality gas sensor, reliable and corresponding. ● The intelligent algorithm of the microprocessors can compensate for the drift of gas sensor. ● The precision temperature sensor is a supplement of the monitoring of the environment temperature, which completely eliminates false alarms. ● LEDs indicate the detector status of normal, alarm and fault. ● The shell of the detector use fire-resistant ABS engineering plastic, clean and generous. Technical Specifications 1) Operating power: DC 24V 2) Standby current: 21 mA 3) Alarming current: 28 mA 4) Ambient temperature: −10℃〜+50℃ 5) Operating humidity: ≤95%RH 6) Sound level: >75dB 7) Pressure: 86kPa-106kPa 8) First stabilization period: 3 min 9) Expiration time of sensor: >5 years(in clean air) 10) Alarming threshold: methane: 8% LEL 11) Detecting gas: available to detect natural gas and many other kinds of combustible gas containing methane. 12) Output contact: active contact, available for one-way pulse solenoid valve of DC 12V; the drive capability of solenoid valve: 1000 μF capacity discharge 13) Encoding mode: addressable 14) Wiring: ①White plug: Connecting DC 12V solenoid valve ②Black line: Connecting DC 24V ③White line: Connecting the loop of control panel 15) Dimension: 120mmX86mmX48mm
$20.00TCZS5273 Detector remote indicator light (Hereinafter referred to as remote indicator light)It ismainly used in the bus connection in fire alarm system, It can be used with fire alarm smoke detector,heatdetector and Combination Heat and Smoke Detector.When the installation position of on-site testing equipment is not convenient to ob-serve the alarm state,it can cooperate with the remote indicator light to lead its alarm state to the positioneasy to observe,prompting the field staff to pay attention,so as to better control the scene situation. TCZS 5273 Detector remote indicator features: 1.Two-wire connection with external equipment,convenient on-site wiring 2.Share the address with the matching detection equipment,specifically patrol the indicator light separate-ly,easy to observe the current state of the equipment; 3.Using microprocessor to realize signal processing,using digital signal to communicate with the controller,the work is stable and reliable,and has a good ability to restrain electromagnetic interference TCZS 5273 Detector remote indicator Specification Rated operating voltage DC 24V Working current Monitoring current ≤0.21mA;Starting current ≤0.4mA Operating Environment Class: Indoor atmospheric pressure: 86kPa ~ 106kPa Temperature: 0℃ ~ +50℃ Relative humidity ≤95%, no condensation Indicator green : The fitting equipment shines during inspection Red: the alarm of the matching product is duration bright Electronic encoding method, sharing the same bus coding point with the matching product, the coding range can be set arbitrarily between 1 and 255. Reset mode controller reset Boundary dimension 86mm×86mm Shell material and color ABS, white
$5.50NAJ2214 Addressable Fire Extension Telephone handle works with TCSB5214H or same brand telephone jack It is a bus communication device special for fire protection system. The extension can transmit and receive signals with a Fire Telephone control panel. It is suitable for hotels, restaurants, office buildings, teach buildings, banks, warehouses, libraries, computer rooms and switching rooms. In traditional fire management, some information is managed in the form of paper files. Not only is the data record not comprehensive enough, but also it is difficult to consult and manage because data management is not applied. Tiancheng home safety all-wireless products are combined with the cloud platform, which can fully record and manage all the operation traces of equipment implementation. When the equipment fails, the system will automatically report it to the management party and the maintenance party, and the follow-up inspection and maintenance work will also be recorded in the whole process, so as to change the fire control work mode and further improve the fire control work management efficiency. Frequency Range: 300-3400Hz Operating Current: < 22mA Operating Environment: Temperature: - 10°C~+55°C; Relative Humidity: <95% Function: Matched with NAJ2213&NAJ2215 Dimension: 204 mmx 50mmX 38mm Mounting Hole Distance: 100mm Approval: CCCF
$13.50TC-ZJ402 The wireless signal extender is suitable for home wireless alarm system and industrial wireless alarm system. The repeater uses advanced wireless transceiver technology, built-in efficient anti-collision algorithm, and can set filtering rules, so that the repeater can work reliably in the system. At the same time, the repeater supports multiple groups of channels, so that the repeater can work in complex environments and in the presence of multiple hosts, realizing mutual non-interference, truly avoiding the collision of channels, and greatly improving the coverage of wireless networks. Technical Data All data is supplied subject to change without notice. Specifications are typical at 24V, 25℃ and 50% RH unless otherwise stated. Main power DC5V(Power Adapter) Standby power 3V/2400MAh Power consumption monitoring≤9W , alarm≤2.2W Operation indicator flash when normal Fault indicator on when standby power fails Communication indicator flash when forwarding info Wireless transmission power 19dBm Communication distance ≤500m Communication method 470MHz FSK coded bidirectional Operating environment temperature 10℃~+55℃ relative humidity ≤95% Dimension 130mm in diameter H:48mm Avoid excessive humidity in repeater installation position To ensure the long-term reliability and accuracy of the repeater, the wireless performance should be checked regularly. The free warranty period of this repeater is one year, with lifetime maintenance.
$35.50The detector can work independently or connect with JB-DH-TC5600 electrical fire monitoring equipment through two bus circuits, and realize the functions of leakage detection, temperature detection and output control. It works stably and reliably, and is connected with a variety of residual current transformers according to the magnitude of the over-line current. How to install electric fire monitoring system? Features 1.The Detector and the Electrical Fire Monitoring Equipment use non-polarized two-line system to connect. With mature technology, it is reliable in communication and convenient in cabling. 2. The Detector uses a high-performance CPU, intelligent algorithm and watchdog technology, highly efficient and reliable. 3. The Detector has a built-in passive output control which can connect with one or two loops to alarm leakage. 4. The Detector has the function of self-test which can test the screen and squealers working normally or not. 5. The Detector can set the residual current from 200mA to 1000mA of residual current transformers, which is high- precision detecting and widely used. It can be programmed with address and convenient for commission and maintenance. 6. The alarming temperature can be set from 45℃ to 140℃, high-precision detecting and widely used. It is convenient for commission and maintenance by the setup of addressable code and temperature. 7. The Detector has a good-looking appearance with intuitive showing of LCD information, simple operation and powerful functions, scalability and easy to installation. Technical Specification 1. Operating voltage: AC 220V 2. Operating current: ≤10mA 3. Alarming current: ≤25mA 4. Rated alarming current: 200mA~1000mA, step 1mA 5. Rated alarming temperature: 45℃-140℃, step 1℃ 6. Loop interface: Loop 24V, non-polarized 7. Capability of output terminal: 1A/AC125V,3A/DC24V 8. Response time: ≤10s 9. Rated frequency through the line: 50Hz/60Hz 10. The parameters of residual current transformer can be seen in chapter 5.3 11. Operating environment: Temperature: -10℃~+50℃ Relative Humidity: ≤95%, no condensation Altitude: <5000m 12. IP Grade: IP30 13. Weight: about 420g 14. Standard: GB 14287.2-2014“Electrical fire control system - Part 2: residual current electric fire detectors” GB 14287.3-2014“Electrical fire monitoring systems -Part 3: The temperature electric fire detectors” 4. Structure and Working Principle: 1. Refers to Fig.1 for the appearance of detector 2. Working principle The Detector receives the information from the sensor. When the information sent by the sensor reaches the setup value of threshold, the detector will send audible and visual alarm, and the screen will display the current alarm at the same time. If the Detector has been connect with the loop, the detector can upload alarm, faults and some other information to the electrical fire monitoring equipment and execute the order of the equipment.
$160.00Product Description
TC-ZJH5008 loop extender is powered by DC24V, and the input and output of bus signals are electrically isolated, which can enhance the anti-interference ability of the whole fire alarm system and has the function of extending the communication distance of the detector bus.
II. Characteristics
1. Built-in isolated power supply with strong interference capability;
2. And the bus and the DC24V power line are non-polar connected;
3. Raise bus voltage and extend bus communication distance;
4. With output short circuit detection function;
5. Up to 255 devices can be attached;
6. Plug-in structure, convenient and reliable installation;
Technical Specifications
1. Operating voltage:
Rated working voltage of signal bus: DC24V range: DC17V~DC28V
Power supply rated working voltage: DC24V range: DC18V~DC36V
2. Operating current:
Monitoring current ≤0.3mA
3. Output capacity: 400mA
4. Load capacity and compatibility: 1 ~ 255 bus devices can be connected, compatible with all detector bus devices.
5. Bus extension distance: 1000m
6. Indicator: There is an answer indicator (red). The indicator does not light when it is normal, and the indicator flashes when the detector answers; With an overload indicator (yellow), the indicator is not on when it is normal, and it is always on when the loop extender output is short-circuited.
7. Environment:
pressure: 86 kPa ~ 106 kPa
Temperature: 0℃ ~+55℃
Relative humidity ≤95%, no condensation.
8. Dimensions: 86mm×86mm×40mm (with cover)
9. Material and color: ABS, porcelain white
10. Weight: about 147g (with cover)
11. Mounting hole distance: 60mm

TCDZ516 Isolating Base, mainly applied in bus-based fire detection and alarm system, can isolate the short-circuit detector or wire out of the system to ensure the normal running of other devices. This device can provide bidirectional protection under low power consumption with the inspection method of hardware and software combination. It is applicable to bus-based fire detection and alarm systems of all types.
TCDZ 516 Isolating Base features:
1. share the address with the associating devices
2. the microprocessor is adopted to realize signal processing, and the digital signal is used to communicate with the fire alarm control panel, which works stably and reliably, and has a good ability to suppress electromagnetic interference.
3. electronically coding.
TCDZ 516 Isolating Base specification:
Working voltage: Voltage of signal bus: Bus 24V Range: DC16V~DC28V
Working current:
Vnom: 24V
ISO max: 750mA
ISO min: 280mA
ISC max: 31mA
ISC min: 12mA
IL max: 35mA
IS max: 900mA
IC max: 580mA
ZC max: 0.6Ω
Indicator light:yellow, extinguished in normal monitoring state, and always on during operation
Wire system: Polar two bus connection
Protection level: IP30
Use environment: Temperature: -10℃~+55℃
Relative humidity≤95%, non-condensing
Outline dimension: Dia.100mm, thickness:19mm
Housing material: ABS
Weight: about 76g
Distance between installation holes: 60mm
TC5109 Intelligent Fire Alarm Control Panel Core Functions: Fire Alarm Monitoring, Fault Detection & Indication, Device & Zone Management, Linkage Control, System Operation & Control, Communication & Networking, Display & Output.
Integral of fire monitoring, information transmission and fire protection safety management RS232 interface is switched to RS485 interface by internal interface board, thus to be connected with TC5000 series such as TC5109 automatic Fire Alarm Control Panel Display general layout, alarm plane figure and system graph with the functions of information display, duty management, evacuation indication, query, printing, etc Man-machine friendly, vivid and convenient operation. Model No.: TCCRT-5017B Voltage: AC220V(AC185V~AC242V), 50Hz+1Hz or AC110V (AC90V~AC120V),60Hz +1Hz Current: 300mA LED Screen: 19 inch Operating Environment: Temperature: 0°C~ +40°C; Relative Humidity:≤95% Interface: RS232, RS485, LAN/WAN Dimension (LxWxH): 482mmx 1 83mm x444mm Approval: CCCF, CE
$530.00Alarm location display panel fire floor screen
TCFS5089 TC brand LPCB approval professional intelligent addressable fire alarm system.
Model No.: TCFS5089
It is used to display the fire location and related information of a certain floor or fire zone, and at the same time send out an sounder strobe alarm signals to inform people in nearby areas.
* Display Fire Alarm position and information for certain floor or fire protection zone, give out audio and visual alarm signal to inform nearby personnel
* Max 12 TCFS5089 Fire Display Panel per loop
* Wiring: four bus system
* Display range: any 512 alarm points within nearby 5 loops on its locating loop mainboard
* English comment display
* Dimension: 180mm× 110mm× 40mm
Voltage
Loop : DC24V(16V-28V); Power: DC24V(20V-28V)
Current
Standby Current: loop:≤1.1 mA, Power: < 9mA;
Alarm Current: Loop: ≤2mA, Power:≤45mA
Operating Environment
Temperature: -10°C~+50°C; Relative Humidity:≤9 5%, non-condensing
Wiring
Four-wired
Dimension (LxWxH)
180mmX 110mmx40mm (with base)
Approval
CCCF, CE

TCFSH5206 Water Proof Box For Outdoor Sounder Strobe Fire Alarm 24V
Protection rating: IP67
Material and color of enclosure: ABS
Dimension(L×W×H): 185mm×185mm×75mm
Please shop compatible sounder strobe TC5228
Or confirm the waterproof box is suitable for yours.

TCFSH5231 IP67 Water Proof Box For Module And MCP Fire Security System Wiring
Protection rating: IP67
Material and color of enclosure: ABS
Dimension(L×W×H): 147mm×119mm×79mm
Please buy compatible fire alarm MCP TCSB5264 or confirm the suitable size

TCFSH5203 IP67 Outdoor Sounder Box for TC5231 Fire Alarm Sounder Strobe
Protection rating: IP67
Material and color of enclosure: ABS
Dimension(L×W×H): 147mm×119mm×79mm
Shop below compatible fire sounder strobe

TCMK5413W wireless input/output module is suitable for installation in public places, factories and other environments. When there is a fire alarm, the module can not only send an alarm signal to the control panel through wireless communication technology after receiving the closing signal, but also output the closing signal for connection with other equipment. It can connect to smoke exhaust valves, air supply valves, fire dampers, etc., and accept action response signals from the equipment. It is with input inspection and output inspection functions. Technical Data All data is supplied subject to change without notice. Specifications are typical at 24V, 25℃ and 50% RH unless otherwise stated. Battery CR17450 Rated Operating Voltage 3V Operating current monitoring current≤14uA , alarm current≤10mA Coding method automatically assigned when networking Radio frequency transmit power<20dBm Communication method 470MHz FSK coded bidirectional Communication distance ≤500m Operating environment temperature 10℃~+55℃ relative humidity ≤95% Dimension 101mm*137mm*43mm Weight 170g The 470MHz wireless communication technology is adopted, and no embedded wiring is needed, so the engineering installation is convenient and quick; With battery low voltage detection function, it can reflect the battery power situation in time; The microprocessor is used to realize signal processing, and the digital signal is used to communicate with the control panel, which works stable and reliably, and has a good ability to suppress electromagnetic interference.
$28.50TCDZ517S Sounder base is mainly used in fire alarm systems that require bus-connection. After encoding, it can be used in conjunction with fire alarm smoke detectors and heat detectors. (Compatible with TC5161 and TC5162 and TC5163) When the on-site detection equipment issues an alarm, the sound base can be linked for sound output, prompting the on-site staff to pay attention, so as to better control the on-site situation.
TCDZ 517S Sounder Base characteristic:
1.Two-wire connection with external equipment, convenient on-site wiring;
2.The address is set by electronic coding, no dial switch is needed, and the airtightness is increased in the structure;
3.Use microprocessor to realize signal processing, and use digital signal to communicatewith controller, work stably and reliably, and have a good ability to suppress electromag.
Specification:
Rated working voltage: DC24V
Working current: monitoring current ≤0.18mA starting current ≤5.5mA
Sound pressure level: 65dB ~ 115dB (A weighting)
Coding method: electronic coding method, occupying a bus coding point, the coding range can be set arbitrarily between 1 and 255
Reset method: controller reset
Use environment: Indoor
atmospheric pressure: 86kPa~ 106kPa
Temperature: 0℃~+50℃
Relative humidity ≤95%, non-condensing
Shell material and color: ABS, milky white
Pitch shift periodic: Φ110mm×29mm
Sound type
Sound pressure level: 3.5s~4.5s/0.1s~0.4s
Security Alarms